Warning | Risk of injury during testing and repair operations related to pyrotechnical components | Do not expose pyrotechnical component parts to temperatures above 100 °C or 212 °F. Disconnect current supply when working on such component parts. | |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Information, assessment and legal requirements when working with, handling and storing pyrotechnical components | |||
| Install | ||
1 | Read through service information for disabling the front passenger airbag when a rear-facing child seat has been fitted | ||
| |||
2 | Attach plug connection to front passenger airbag | Model 124, 126 | |
Model 126 | |||
Depending on the model and the version, 1 or 2 connectors must be attached to the front passenger airbag and appropriate replacement resistors must be removed. | |||
3 | Remove replacement resistor | ||
4 | Remove adhesive label in area of front passenger airbag or render invalid | ||
5 | Remove adhesive label from owner's manual or render invalid | In the airbag chapter of the owner's manual. |
Powiązane dokumenty
- ah5400p000101a Wskazówki dotyczące zapobiegania uszkodzeniom elementów elektronicznych na skutek rozładowania potencjału elektrostatycznego
- ah9100z000010a Wskazówki, oceny i prawne przepisy dotyczące wykonywania prac, składowania i postępowania z elementami pirotechnicznymi
- ar9160p0680c
- as9100z000801a Niebezpieczeństwo obrażeń podczas napraw i czynności diagnostycznych związanych z elementami pirotechnicznymi
- si9160p0002a