S86.30-4544-09
1 | Cabinet | 4 | Screw | 9 | Elbow fitting | ||
2 | Bolts | 5 | Check strap | 10 | Hose | ||
3 | Bolts | 6 | Fresh water tank | 11 | Passage |
6 | Fresh water tank |
12 | Elbow fitting |
13 | Seal |
14 | Nut |
15 | Hoses |
B146/2 | Fresh water fill level sensor |
S86.30-4545-05
6 | Fresh water tank |
6.1 | Fitting |
A | Dimension |
S86.30-4563-11
| Remove/install | ||
1 | Remove cabinet (1) | ||
2 | Unscrew screws/bolts (2) | ||
3 | Remove bolts (3) | Installation: Before tightening bolts (3) ensure that the distance between the fittings (6.1) and the cabinet (1) is correct. Must be approx. 5 mm. | |
If the distance is too low | |||
| |||
Align fresh water tank (6) accordingly | |||
4 | Remove fresh water tank (6) toward rear from cabinet (1) | ||
5 | Remove shutoff valve from fresh water tank (6) | When replacing fresh water tank (6). | |
6 | Unscrew bolt (4) and remove check strap (5) from fresh water tank (6) | When replacing fresh water tank (6). | |
7 | Pull elbow fitting (9) out of passage (11) and lay down to side with hose (10) | When replacing fresh water tank (6). | |
8 | Remove passage (11) | When replacing fresh water tank (6). | |
Installation: Check passage (11) for damage. | |||
Installation: Ensure that grommet (11) is seated correctly. | |||
If passage (11) is damaged | |||
| |||
Replace passage (11) | |||
9 | Remove fresh water fill level sensor (B146/2) | When replacing fresh water tank (6). | |
10 | Remove water pump in fresh water tank (6) | When replacing fresh water tank (6). | |
11 | Unscrew nut (14) and remove elbow fitting (12) together with hoses (15) | When replacing fresh water tank (6). | |
Installation: Check seal (13) for damage. | |||
If seal (13) is damaged | |||
| |||
Replace seal (13) | |||
| Check | ||
12 | Check dimension (A) of fitting (6.1) on fresh water tank (6) | Dimension (a) must be 80 mm. | |
If deviations are present | |||
| |||
Shorten fittings (6.1) accordingly | |||
13 | Install in the reverse order |