S86.30-4546-09
1 | Fresh water tank | 3 | Shutoff cock | 5 | Threaded stud | ||
2 | Elbow fitting | 4 | Threaded stud |
| Remove | ||
1 | Remove fresh water tank (1) | ||
| Disassemble | ||
2 | Unscrew elbow fitting (2) from shutoff valve (3) | Hold shutoff valve (3). | |
3 | Unscrew shutoff valve (3) from fresh water tank (1) | ||
| Clean | ||
4 | Remove sealing frame on threaded studs (4, 5) and clean threaded studs (4, 5) | ||
| Assemble | ||
5 | Replace sealing strip on threaded studs (4, 5) | Pre-compressed seal strip | |
6 | Unscrew shutoff valve (3) from fresh water tank (1) | ||
7 | Unscrew elbow fitting (2) from shutoff valve (3) | Hold shutoff valve (3). | |
| Check | ||
8 | Fill fresh water tank (1) | ||
9 | Check shutoff valve (3) for leakage in repair area | ||
10 | Open shutoff valve (3) and remove fresh water tank (1) | Collect fluid running out with suitable vessel. | |
| Install | ||
11 | Install fresh water tank (1) |