ar8355d5300r

Remove/install refrigerant compressor

Typ ar · temat 83.55 · wersja 0100 · 2013-08-26

Dotyczy: MODEL 909 with ENGINE 646 with CODE HH9 (Regulated air conditioning (Tempmatic))

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 3 Nadwozie › 83 Klimatyzacja › 83.55 Sprężarka czynnika chłodniczego — Seria 646 · Seria 909

EinPAS 39 Ogrzewanie/ wentylacja/ chłodzenie › 39.15 Klimatyzacja › 39.15.40 Sprężarka układu klimatyzacji — Seria 646 · Seria 909

AR83.55-D-5300R

Remove/install refrigerant compressor

06.08.2013

MODEL

909 with ENGINE 646

with CODE HH9 (Regulated air conditioning (Tempmatic))

Remove/install refrigerant compressor

1

Refrigerant compressor

2

Refrigerant line (intake side)

3

Refrigerant line (pressure side)

4

Sealing ring

5

Sealing ring

6

Screw

7

Screw

8

Bracket

9

Screw

10

Electrical line

D83.55-1134-06

Danger !

Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant.

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well-ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained.

AS83.00-Z-0001-01A

Protect air conditioning circuit and components from moisture when carrying out repair work

AH83.30-N-0005-01A

Procedure for a damaged or leaky air conditioning system

AH83.30-N-0004-01A

Notes on handling refrigerant R134a

AH83.30-N-0003-01A

Remove/install

1

Remove fluid reservoir

AR83.30-D-6520F

Installation: Replace receiver/drier.

2

Slacken poly-V-belt and detach from refrigerant compressor (1)

AR13.22-D-1202R

3

Disconnect electrical line (10) at refrigerant compressor (1)

4

Unscrew screws/bolts (6, 7) and detach refrigerant lines (2, 3) at refrigerant compressor (1)

Compressor oils (specification 362.0)

BB00.40-P-0362-00A

Installation: Replace sealing rings (4, 5) and moisten with compressor oil.

Close off refrigerant lines (2, 3) and refrigerant compressor (1) with stop plugs.

Screw/bolt, refrigerant line on refrigerant compressor

*BA83.30-N-1009-02A

Record plug

*129589009100

5

Remove screws/bolts (9) and remove refrigerant compressor (1)

Screw/bolt, refrigerant compressor/bracket

*BA83.55-N-1001-01B

6

Install in the reverse order

Refrigerant lines

Number

Designation

MODEL 909
with CODE HH9 (Regulated air conditioning (Tempmatic))

BA83.30-N-1009-02A

Screw/bolt, refrigerant line on refrigerant compressor

Nm

21 (2)

Refrigerant compressor

Number

Designation

MODEL 909
with CODE HH9 (Regulated air conditioning (Tempmatic))

BA83.55-N-1001-01B

Screw/bolt, refrigerant compressor/bracket

Nm

20

Remove/install refrigerant compressor

129 589 00 91 00

Record plug