AR83.30-P-6520C | Remove/install fluid reservoir | 15.11.11 |
MODEL 129 as of 1.6.96 with CODE (581) Automatic air conditioning
P83.30-0631-12
1 Fluid reservoir
2 Pressure line
3 Pressure line
4 Refrigerant pressure sensor connector
5 Refrigerant temperature sensor connector
B12 Refrigerant pressure sensor
B12/1 Refrigerant temperature sensor
Modification notes
| Remove/install | ||
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
| Procedure for a damaged or leaky air conditioning system | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models with air conditioning | |
| Notes on handling R134a refrigerant | All models with R134a refrigerant | |
| In the event of air conditioning malfunctions due to leaks, contamination or ice formation, a new accumulator (1) is generally to be installed when repairing or exchanging the refrigerant compressor | ||
1 | Drain air conditioning (recycle), evacuate, charge, check for leakage | When filling the air conditioning system, feed extracted quantity of compressor oil back into the refrigerant circuit. | |
2 | Remove left front lamp unit | Standard headlamp | |
2 | Xenon headlamp | ||
3 | Remove refrigerant pressure sensor (B12) at accumulator (1) | ||
4 | Release and disconnect connector (5) at refrigerant temperature sensor (B12/1) | ||
5 | Remove refrigerant temperature sensor (B12/1) at accumulator (1) | Installation: Replace sealing rings and moisten with compressor oil | |
| |||
6 | Remove pressure lines (2, 3) at accumulator (1) | Installation: When connecting the pressure lines, moisten thread with compressor oil | |
| |||
7 | Install in the reverse order | When replacing the receiver/drier add the prescribed amount of refrigeration oil. | |
8 | Switch on the air conditioner and allow the engine to idle for roughly 4 minutes. | Set temperature to "" Blowers to max. | |
9 | Check air conditioning for proper operation | The air outlet temperature at the center air vent may not sink below + 5 0C, or | |
perform diagnosis according to diagnosis manual | |||
10 | Inspect the air conditioning circuit for leaks | Air conditioning system leak detector |
Air conditioning
Number | Designation | Model | |
BA83.30-P-1003-01A | Lines to fluid reservoir | Nm | 17 |
BA83.30-P-1008-01A | Refrigerant temperature sensor at accumulator | Nm | 6 |
Refrigerant compressor
Number | Designation | Refrigerant | ||
BF83.55-P-1005-01A | Additional oil filling capacity when replacing receiver/drier | Compressor oil | cm3 | 10 |
Specifications for Operating Fluids | Sheet | |||
Refrigerant compressor
Powiązane dokumenty
- ah8330n000301a Wskazówki dotyczące postępowania z czynnikiem chłodzącym R134a
- ah8330n000401a Postępowanie przy uszkodzonym lub nieszczelnym układzie klimatyzacji
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ar8210p4730a
- ar8210p4730b
- ar8330p5430c
- as8300z000101a Niebezpieczeństwo wybuchu na skutek prac spawalniczych lub lutowniczych na zamkniętym układzie klimatyzacji. Niebezpieczeństwo zatrucia na skutek wdychania przegrzanych oparów czynnika chłodzącego. Niebezpieczeństwo obrażeń na sk