AR83.30-P-5430C | Removing and installing refrigerant pressure sensor | 12.7.10 |
MODEL 129 as of 1.6.96 with CODE (581a) Air conditioning (automatic)
P83.30-0637-12
1 Fluid reservoir
2 Connector, refrigerant pressure sensor
B12 Refrigerant pressure sensor
| Removal, installation | ||
1 | Empty air conditioning (recycle) | Installation: Evacuate air conditioning system, recharge, check for leakage and proper function by allowing engine to idle only for first 4 minutes. | |
2 | Unhook and disconnect connector (2) on refrigerant pressure sensor (B12) | ||
3 | Remove refrigerant pressure sensor (B12) from fluid reservoir (1) | Plug opening on fluid reservoir Installation: Replace sealing rings and moisten with compressor oil. | |
| |||
4 | Reinstall in opposite order |
Air conditioning