Shown on vehicle with refrigerant R134a |
1 | Filling connection |
2 | High pressure pipe |
3 | Air conditioning service unit |
4 | Filling connection |
5 | Low pressure pipe |
P83.30-4950-06
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
Notes on handling refrigerant R1234yf | |||
Draining | |||
1 | Open maintenance flap. | ||
2 | Connect air conditioning service unit (3) to filler connection (1) of high pressure line (2) and to filler connection (4) of low-pressure line (5). | ||
| 000 588 04 82 00 Air conditioning service unit R134a | ||
| 000 588 10 82 00 R1234yf air conditioning service unit | ||
When operating the air conditioning service unit (3), proceed in accordance with the operator's manual from the manufacturer. | |||
3 | Extract refrigerant. | When operating the air conditioning service unit (3), proceed in accordance with the operator's manual from the manufacturer. | |
4 | Note down extracted quantity of refrigerant oil in refrigerant circuit. | ||
5 | Replace drier cartridge. | ||
Evacuate | |||
6 | Clean refrigerant with air conditioning service unit (3) and evacuate refrigerant circuit. | When operating the air conditioning service unit (3), proceed in accordance with the operator's manual from the manufacturer. | |
| Check | ||
7 | Perform vacuum test using air conditioning service unit (3). | When operating the air conditioning service unit (3), proceed in accordance with the operator's manual from the manufacturer. | |
Filling | |||
8 | Add new compressor oil to refrigerant circuit using air conditioning service unit (3) according to the quantity of refrigerant oil noted during extraction. | ||
| Compressor oils (specification 362.1) | ||
| |||
| |||
When operating the air conditioning service unit (3), proceed in accordance with the operator's manual from the manufacturer. | |||
Use approved compressor oil only. If it is proven that a different compressor oil has been used, we will refuse to reimburse costs within the warranty and goodwill period. Daimler AG reserves the right to perform reexaminations. | |||
Depending on the repair case, the quantity of refrigerant oil must be corrected accordingly. | |||
| |||
Correct oil level in air conditioning system if system is suddenly drained. | |||
Correct oil level in air conditioning system after replacing parts. | |||
Additional oil filling quantity when replacing condenser | |||
Additional oil filling quantity when replacing evaporator | |||
Additional oil filling quantity when replacing intake line | |||
Additional oil filling quantity when replacing pressure line | |||
Additional oil filling quantity after replacement of desiccant cartridge | |||
Additional oil filling quantity after replacement of refrigerant compressor | |||
Correct oil level in air conditioning system in event of repair or slow loss of refrigerant. | |||
9 | Fill air conditioning system using air conditioning service unit (3). | When operating the air conditioning service unit (3), proceed in accordance with the operator's manual from the manufacturer. | |
Filling capacity of air conditioning/automatic air conditioning | |||
Filling capacity of air conditioning/automatic air conditioning | |||
10 | Check pressure using air conditioning service unit (3). | When operating the air conditioning service unit (3), proceed in accordance with the operator's manual from the manufacturer. | |
In the event of a pressure drop during the pressure test | |||
| |||
Check air conditioning system for leakage. | |||
11 | Disconnect air conditioning service unit (3). | When operating the air conditioning service unit (3), proceed in accordance with the operator's manual from the manufacturer. | |
12 | Close maintenance flap. |
Powiązane dokumenty
- ah8330n000301a Wskazówki dotyczące postępowania z czynnikiem chłodzącym R134a
- ah8330n000401a Postępowanie przy uszkodzonym lub nieszczelnym układzie klimatyzacji
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ah8330p000302a Wskazówki dotyczące obchodzenia się z czynnikiem chłodzącym R1234yf
- ar8330p1761sr
- ar8330p1761sre
- ar8330p5251sr
- ar8330p5253sr
- ar8330p6521sr
- as8300z000601a Zagrożenie zatruciem na skutek wdychania przegrzanych oparów czynnika chłodzącego R134a. Niebezpieczeństwo obrażeń w przypadku kontaktu płynnego czynnika chłodzącego R134a ze skórą i oczami oraz podczas obchodzenia się z
- as8300z000701a Zagrożenie pożarem na skutek zapłonu czynnika chłodzącego R1234yf przy kontakcie z gorącymi elementami. Niebezpieczeństwo zatrucia na skutek wdychania przegrzanych oparów czynnika chłodzącego. Niebezpieczeństwo obrażeń w przyp
- bb0040p036201a
- ws8300p0031b
- ws8300p0034b