D83.30-A002-09
1 | Condenser | 3 | Guide | |
2 | Bracket | 4 | Clip |
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Warning | Risk of injury. Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | |
Caution | Risk of injury caused by scraping or cutting body parts on sharp vehicle parts | Always wear protective gloves when working on or near sharp and non-deburred vehicle parts. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
Notes on handling refrigerant R134a | |||
Notes on handling refrigerant R1234yf | |||
| Remove/install | ||
1 | Remove air filter housing. | ||
2 | Discharge air conditioning system. | ||
Installation: Always replace receiver drier. | |||
3 | Remove refrigerant line between condenser (1) and front connecting point on longitudinal member of condenser (1) and seal with suitable stop plugs. | ||
Record plug | |||
4 | Remove refrigerant line between condenser (1) and refrigerant compressor of condenser (1) and seal with suitable stop plugs. | ||
Record plug | |||
5 | Remove electric fan. | ||
6 | Unclip automatic transmission oil cooler and place to one side with connected lines. | ||
7 | Remove cover for refrigerant lines. | ||
8 | Release clips (4) using suitable tool, unclip holder (2) from guides (3) and remove condenser (1). | If the condenser (1) is reused. | |
| |||
Replace the fluid reservoir. | |||
9 | Transfer pressure sensor for refrigerant. | If condenser (1) is replaced. | |
10 | Install in the reverse order. |
129 589 00 91 00
Record plug
Powiązane dokumenty
- ah0000p500001a Wskazówki dotyczące zapobiegania uszkodzeniom na skutek zabrudzeń i ciał obcych
- ah8330n000301a Wskazówki dotyczące postępowania z czynnikiem chłodzącym R134a
- ah8330n000501a Ochrona obwodu i elementów układu klimatyzacji przed wilgocią podczas napraw
- ah8330p000302a Wskazówki dotyczące obchodzenia się z czynnikiem chłodzącym R1234yf
- ar0910s1150eg
- ar2040d5000tsc
- ar2755d1000tsc
- ar8330d0008tsr
- ar8330d1760ts
- ar8330d5445tsf
- ar8330d6520tsr
- ar8330d7830tsr
- as0000z000201a Niebezpieczeństwo zranienia skóry i oczy na skutek kontaktu z gorącymi lub żarzącymi się przedmiotami
- as0000z001701a Niebezpieczeństwo obrażeńo elementy pojazdu o ostrych krawędziach.
- as8300z000601a Zagrożenie zatruciem na skutek wdychania przegrzanych oparów czynnika chłodzącego R134a. Niebezpieczeństwo obrażeń w przypadku kontaktu płynnego czynnika chłodzącego R134a ze skórą i oczami oraz podczas obchodzenia się z
- as8300z000701a Zagrożenie pożarem na skutek zapłonu czynnika chłodzącego R1234yf przy kontakcie z gorącymi elementami. Niebezpieczeństwo zatrucia na skutek wdychania przegrzanych oparów czynnika chłodzącego. Niebezpieczeństwo obrażeń w przyp