AR83.30-D-6540NA | Install/remove condenser | 16.1.01 |
MODELS WD1, WD2, WD3, WD6, WD7
MODEL 903.67 with CODE (ZU7) National version for Canada
MODEL 903.67 with CODE (ZU8) National version for USA
MODEL 903.67 with CODE (ZU9) National version for Mexico
MODELS XD1, XD2, XD3, XD4, XD6, XD5, XD7, YD1, YD2, YD3, YD4, YD6, YD5, YD7 with CODE (HH9) Automatic air conditioning "Tempmatic"
MODELS 903.61 /66, 904.61 /66
with CODE (HH9) Automatic air conditioning "Tempmatic"
with CODE (ZU7) National version for Canada
MODELS 903.61 /66, 904.61 /66
with CODE (HH9) Automatic air conditioning "Tempmatic"
with CODE (ZU8) National version for USA
MODELS 903.61 /62 /66, 904.61 /62 /66
with CODE (HH9) Automatic air conditioning "Tempmatic"
with CODE (ZU9) National version for Mexico
D83.30-1109-06
1 Capacitor
2 Refrigerant line for refrigerant compressor/condenser
3 Refrigerant line of condenser/fluid reservoir
4 Lower half of holder
5 Additional fan
6 Upper half of holder
7 additional fan connector
| Remove/Install | ||
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models fitted with air conditioning | |
1 | Discharge air conditioning system | ||
2 | Remove front bumper | ||
3 | Remove headlamp | ||
4 | Remove front end cross member together with front grille | ||
5 | Disconnect refrigerant lines (2, 3) from condenser (1) | | |
| |||
6 | Disconnect additional fan connector (7) | ||
7 | Remove additional fan (5) together with bracket (6) | ||
8 | Remove bracket (4) at bottom | ||
9 | Disconnect condenser (1) from radiator | Installation: top up compressor oil. Replace lower clips with clip fasteners. | |
10 | Install in the reverse order | ||
11 | Evacuate the air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak. |
Refrigerant lines
Number | Designation | Model | Models | |
BA83.30-N-1001-02A | Refrigerant line of refrigerant compressor/condenser to refrigerant compressor | Nm | 33 | 33 |
BA83.30-N-1003-02A | Refrigerant line on condenser/fluid reservoir on condenser | Nm | 17 | 17 |