ar8320d1000f

Remove and install regulating valve for heating

Typ ar · temat 83.20 · wersja 0100 · 2013-06-20

Dotyczy: MODEL 909 without CODE HH9 (Regulated air conditioning (Tempmatic))

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 3 Nadwozie › 83 Klimatyzacja › 83.20 Ogrzewanie — Seria 909

EinPAS 39 Ogrzewanie/ wentylacja/ chłodzenie › 39.15 Klimatyzacja › 39.15.13 Przewód sztywny/elastyczny/zawór — Seria 909

AR83.20-D-1000F

Remove and install regulating valve for heating

04.06.2013

MODEL

909

without CODE HH9 (Regulated air conditioning (Tempmatic))

Remove and install regulating valve for heating

1

Screw

2

Screw

3

Electrical wiring harness

4

Heater regulating valve

5

Seal

6

O-ring

D83.20-1107-11

Remove/install

Danger !

Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries

No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

1

Disconnect ground line from battery

Notes on battery

AH54.10-P-0001-01A

2

Remove cover of radio installation slot

3

Remove glove box

4

Remove stowage compartment below pen holder

5

Remove covering on instrument cluster

AR68.10-D-1550F

6

Remove instrument cluster

AR54.30-D-6015F

7

Remove stowage compartment above glove compartment

AR68.10-D-1515F

8

Remove speaker

AR82.62-D-7833F

9

Remove cover on center part of dashboard

AR68.10-D-1190F

10

Remove air conditioning pushbutton control unit

AR83.25-D-1124FB

11

Remove drawer

AR68.10-D-1195F

12

Remove top part of dashboard

AR68.10-D-1020F

13

Remove central electric unit

AR54.25-D-1382F

14

Remove air nozzles in instrument panel

AR68.10-D-1110F

15

Remove dashboard

AR68.10-D-1000F

16

Remove heater control cable

AR83.20-D-1400F

17

Remove ventilation box

AR83.10-D-0010F

18

Remove heater housing

AR83.25-D-1000FD

19

Remove seal (5)

Installation: Clean sealing surface and install new seal (5).

20

Remove electrical wiring harness (3)

21

Unscrew screws/bolts (1, 2) and remove heater regulating valve (4) with O-rings (6)

Installation: Replace O-rings (6).

22

Install in the reverse order

23

Set time on instrument cluster

24

Set time on timer for auxiliary heater

MODEL 909
with CODE H12 (Auxiliary heater (warm water))
without CODE HH9 (Regulated air conditioning (Tempmatic))
MODEL 909
with CODE H86 (Chronometer with relay for independent heating)
without CODE HH9 (Regulated air conditioning (Tempmatic))
MODEL 909
with CODE HZ5 (10 kW warm water auxiliary heater with timer)
without CODE HH9 (Regulated air conditioning (Tempmatic))

25

Connect diagnostic system and perform quick test

AD00.00-D-2000-04F

Delete DTC memory if necessary.

Powiązane dokumenty