S22.10-A011-78
1 | Fastening bracket | 5 | Bolts | |
2 | Front axle shaft | 6 | Screw | |
3 | Electrical wiring harness | 7 | Tubular frame | |
4 | Screw |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Topical note | Notes on threaded connections fastened using a tightening angle-based tightening process | ||
Topical note | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | ||
| Remove/install | ||
1 | Remove right front axle shaft (2). | ||
2 | Remove electrical vacuum pump. | ||
3 | Support axle drive module and secure on mounting plate. | ||
| 000 588 11 62 00 Major assembly mount | ||
| 000 588 10 62 00 Support plate | ||
When securing axle drive module, ensure that retaining belt is routed above axle drive module and below power electronics. | |||
4 | Unclip electrical wiring harness (3) at line bracket (arrow A). | Clip remover | |
5 | Remove screws (4). | Screw, diagonal strut to mounting support | |
6 | Remove bolts (5). | Screw, mounting support to axle drive module frame | |
7 | Remove screw/bolts (6). | Screw, mounting support elastomer bearing to axle drive module | |
8 | Remove mounting support (1) from tubular frame (7) and axle drive module. | ||
9 | Check elastomer bearings of mounting support (1) for damage. | If damage is detected, | |
| |||
replace elastomer bearing. | |||
10 | Install in the reverse order. |
452 589 01 63 00
Clip remover
Powiązane dokumenty
- ah0000p002001a Wskazówki dotyczące połączeń śrubowych tworzonych według kąta dokręcenia
- ah0000z030001a Ogólne wskazówki dotyczące pojazdów z instalacją wysokiego napięcia i/lub akumulatorem litowo-jonowym i/lub gazowym systemem napędu oraz osobistego wyposażenia ochronnego
- ar2210s0009f
- ar3330s0622f
- ar4305s0001f
- as0000z003501a Zagrożenie życia podczas prac przy elementach i systemach U >=30 V napięcie zmienne (AC) bądź U >=60 V napięcie zmienne
- ws0100p0092b
- ws2600p3309b