D20.20-A013-79
Shown with CODE HH4 (THERMOTRONIC automatic air conditioning) |
1 | Radiator unit | 2 | Refrigerant condenser | 3 | Air duct segments |
D20.20-A014-79
Shown with CODE HH4 (THERMOTRONIC automatic air conditioning) |
1 | Radiator unit | 4 | Assembly carrier | 5 | Holder |
Warning | Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. | |
Caution | Risk of injury caused by scraping or cutting body parts on sharp vehicle parts | Always wear protective gloves when working on or near sharp and non-deburred vehicle parts. | |
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
| Remove/install | ||
1 | Remove fan unit. | ||
2 | Remove front bumper. | ||
3 | Remove air duct segments (3) of the cooler unit (1). | The air duct segments (3) are attached to the cooler unit (1) in multiple places. | |
4 | Unhook the left and right catch hooks (arrows) on the cooler unit (1), remove the condenser (2), and secure against dropping down. | Engine 654.9 in model 907.1/2/6 | |
Installation: Guide the condenser (2) into the upper guides on the cooler unit (1). | |||
5 | Remove the holders (5). | ||
6 | Press the cooler unit (1) in the direction of the arrow (arrow A) and remove upwards (arrow B) out of the assembly carrier (4). | Aid of helper required. | |
Installation: Be sure that the cooler unit (1) is seated correctly in the guides in the assembly carrier (4). | |||
7 | Install in the reverse order. |