ar0940b591002a

Check control unit.

Typ ar · temat 09.40 · wersja 0100 · 2016-02-12

Dotyczy:

Niedostępne w języku „pl”; wyświetlono w języku Angielski.

Umiejscowienie

Grupa funkcyjna 1 Silnik › 09 Zasysanie powietrza, doładowanie › 09.40 Turbosprężarka — Seria 357 · Seria 364 · Seria 372 (modele 9**) · Seria 376 · Seria 382 · Seria 384 · Seria 386 · Seria 390 · Seria 397 · Seria 398 · Seria 427 · Seria 435 · Seria 437 · Seria 441 · Seria 443 · Seria 615 · Seria 616 · Seria 617 · Seria 619 · Seria 651 · Seria 652 · Seria 674 · Seria 675 · Seria 676 · Seria 677 · Seria 678 · Seria 679 · Seria 682 · Seria 684 · Seria 685 · Seria 693 · Seria 694 · Seria 695

EinPAS 15 Silnik › 15.30 Ssanie powietrza/ doładowanie › 15.30.31 Siłownik/ nastawnik/ cylinder — Seria 357 · Seria 364 · Seria 372 (modele 9**) · Seria 376 · Seria 382 · Seria 384 · Seria 386 · Seria 390 · Seria 397 · Seria 398 · Seria 427 · Seria 435 · Seria 437 · Seria 441 · Seria 443 · Seria 615 · Seria 616 · Seria 617 · Seria 619 · Seria 651 · Seria 652 · Seria 674 · Seria 675 · Seria 676 · Seria 677 · Seria 678 · Seria 679 · Seria 682 · Seria 684 · Seria 685 · Seria 693 · Seria 694 · Seria 695

Dotyczy też silników/skrzyń biegów: 341 ***, 366 ***, 377 9**, 383 ***, 385 ***, 392 ***, 394 ***, 396 ***, 417 ***, 612 ***, 697 ***, 699 ***

AR09.40-B-5910-02A

Check control unit.

OM 366 A (372.9, 377.9), M 366 LAG (376.9)

Check control unit.
Check control unit.

124 589 15 21 00

Analyzer

000 589 75 63 00

Adapter

Check control unit.

B09.40-0016-11

Check the relief valve (1) for external damage. In case of external deformation or if adjustment has been changed, replace the complete turbocharger.

Install manual pump (2) into the intake pipe (3) of the relief valve (1) and apply 1.25 bar pressure.

Note that the maximum pressure for the test should not exceed 2 bar, since the diaphragm may be damaged.

If the relief valve membrane (1) is damaged, the pressure will exit between the valve body and the stem, at the location shown by the arrow. In this case, replace the complete turbocharger.

The relief valve test (1) to be carried out without the manual pump equipped with pressure gauge requires care and criteria to be adopted:

It may be performed using a pressure gauge with a scale up to 5 bar, however, it shall have an adjusting log regulator to control the pressure, which may not exceed 2 bar.

For this control of the turbocharger, the engine must be stopped, and the compressed air can exit from an outside line or one of the vehicle's reservoirs. The compressed air must be clean and dry.