1 | Screw |
2 | Electrical connector |
L20/1 | Electric machine rotor rpm sensor 1 |
P08.40-A009-12
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Topical note | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | ||
Notes on safety-relevant components | |||
| Remove/install | ||
1 | Drain rear axle differential oil. | ||
2 | Disconnect electrical connection (2). | ||
3 | Clean area around electric machine rotor rpm sensor 1 (L20/1). | Assembly cleaner | |
4 | Remove screw (1). | ||
5 | Take out electric machine rotor rpm sensor 1 (L20/1) | ||
6 | Install in the reverse order. |
Powiązane dokumenty
- ah0000z001901a Wskazówki dotyczące elementów wpływających na bezpieczeństwo
- ah0000z030001a Ogólne wskazówki dotyczące pojazdów z instalacją wysokiego napięcia i/lub akumulatorem litowo-jonowym i/lub gazowym systemem napędu oraz osobistego wyposażenia ochronnego
- ar3531p0523eq
- as0000z003501a Zagrożenie życia podczas prac przy elementach i systemach U >=30 V napięcie zmienne (AC) bądź U >=60 V napięcie zmienne