ad0761p600044a

Oxygen sensor signal downstream TWC - Check ME-SFI gasoline injection electrics

Type ad · thema 07.61 · versie 0103 · 2003-06-10

Geldig voor: ENGINE 104.941 /943 /944 /991 /994 as of 1.8.96 with CODE (494a) USA version ENGINE 104.995 with CODE (494a) USA version with CODE (807) Model year 1997 with CODE (808) Model year 1998 with CODE (498) as of Model Year 97 Japanese version ENGINE 111.921 /942 as of 1.9.98, 111.943, 111.944 as of 1.8.96, 111.946 as of 1.6.98, 111.947 /973, 111.975 as of 1.8.96 with CODE (494a) USA version ENGINE 111.945 in MODEL 208.335 /435 as of 1.6.98, 202.020 /080 as of 1.9.98 with CODE (494a) USA version ENG

Niet beschikbaar in “nl”; getoond in Engels.

Plaats

Functiegroep 1 Motor › 07 Mengselvorming › 07.61 Benzine-inspuit- en ontstekingssysteem ME — Serie 202 (modellen 020, 080) · Serie 208 (modellen 335, 435)

EinPAS 15 Motor › 15.45 Motormanagement › 15.45.1 Basisinformatie — Serie 202 (modellen 020, 080) · Serie 208 (modellen 335, 435)

Geldt ook voor motoren/versnellingsbakken: 104 941, 104 943, 104 944, 104 991, 104 994, 104 995, 111 921, 111 942, 111 943, 111 944, 111 945, 111 946, 111 947, 111 973, 111 974, 111 975

AD07.61-P-6000-44A

Oxygen sensor signal downstream TWC - Check ME-SFI gasoline injection electrics

Scope of test

Tester/test connection

Operation/

prerequisite:

Specified value

Possible cause/

remedy

1.0

Oxygen sensor downstream TWC (G3/1)

Oxygen sensor signal

39

(7D)

3

(3A)

3

(3A)

N3/10

N3/10

40

(8D)

20

(28C)

66

(10E)

At coolant temperature

> 80 °C start engine and maintain engine speed of 2000-3000 rpm

for approx. 2 minutes

Engine: at idle speed:

Insert bridges at socket box

Negative or positive deviation from range between 450 to 500 mV must occur once within one minute

Air pump runs, voltage changes to < 40 mV within 60 s

Lead

AD07.61-P-6000-45A

G3/1

ME-SFI control
module (N3/10)