AR83.55-W-5251A | Correct oil level in air conditioning system when replacing refrigerant compressor | 22.3.12 |
MODEL 963, 964 with CODE (D6F) Air conditioning
MODEL 963, 964 with CODE (D6G) Automatic air conditioning
MODEL 963, 964 with CODE (D6H) Stationary air conditioner
Drain | |||
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerants. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been emptied. | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | ||
| Notes on handling R134a refrigerant | ||
1 | Drain new refrigerant compressor | Drain compressor oil via openings for low-pressure and high-pressure line and dispose of it. | |
2 | Drain removed refrigerant compressor | Drain compressor oil via openings for low-pressure and high-pressure line and collect with a suitable measuring cup. | |
Measure | |||
3 | Measure quantity of compressor oil drained from removed refrigerant compressor | ||
Fill | |||
4 | Fill new AC compressor | Fill same quantity of compressor oil that was measured at the removed refrigerant compressor |
참조 문서
- ah8330n000301a 냉매 R134a 취급 관련 지침
- ah8330n000501a 정비 작업 시 에어컨의 회로와 부품들을 습기로부터 보호하십시오.
- as8300z000101a 밀폐된 에어컨에서 용접 작업이나 납땜 작업을 실행할 경우 발생할 수 있는 폭발 위험 과열된 냉매 증기의 흡입으로 인한 중독 위험 액체형 냉매와의 피부 및 안구 접촉에 의한 상�