AR83.55-D-5300B | Remove/install refrigerant compressor | 31.5.99 |
MODEL 901.6, 902.6, 903.6, 904.6, 905.6 with CODE (HH9) Automatic air conditioning "Tempmatic"
MODEL 690.6 with CODE (HH9) Automatic air conditioning "Tempmatic"
D83.55-1101-06
Shown on engine 611
1 Refrigerant compressor
2 Refrigerant line on intake side
3 Refrigerant line on thrust side
4 Sealing ring
5 Sealing ring
6 Screw
7 Screw
8 Bracket
9 Screw
10 Electrical connector
| Remove/Install | ||
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
1 | Discharge air conditioning system | ||
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models fitted with air conditioning | |
2 | Slacken poly V-belt and take it off at refrigerant compressor (1) | ||
3 | Disconnect electrical connector (10) from refrigerant compressor (1) | ||
4 | Remove refrigerant lines (2, 3) on refrigerant compressor | | |
Installation: Install new sealing rings (4, 5) | |||
5 | Unscrew screws (9) and remove refrigerant compressor (1) | Installation: top up compressor oil | |
6 | Install in the reverse order | If refrigerant compressor had to be replaced because of internal fault | |
Replace connection lines (2, 3) together with sealing rings. | |||
Replace expansion valve | |||
7 | Evacuate the air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak. |
Refrigerant lines
Number | Designation | Model | Models | |
BA83.30-N-1009-02A | Screw for refrigerant line on refrigerant compressor | Nm | 21 (2) | 21 (2) |
Refrigerant compressor
참조 문서
- ah8330n000501a 정비 작업 시 에어컨의 회로와 부품들을 습기로부터 보호하십시오.
- ar1322d1202e
- ar8330d1760a
- ar8330d5520a
- as8300z000101a 밀폐된 에어컨에서 용접 작업이나 납땜 작업을 실행할 경우 발생할 수 있는 폭발 위험 과열된 냉매 증기의 흡입으로 인한 중독 위험 액체형 냉매와의 피부 및 안구 접촉에 의한 상�