AR83.30-L-5300A | Remove/install A/C compressor | 12.7.10 |
MODEL 667, 668, 670 with CODE (H03) Air conditioning in front section
L83.30-0005-12
Shown on refrigerant compressor of 904 engine
1 Bolt
2 Manifold
3 Seals
4 AC compressor
5 Combination bracket
6 11/16" screw-in pipe connection
7 7/8" screw-in pipe connection
8 Refrigerant line, low pressure
9 Refrigerant line, high pressure
10 Screw
11 Washer
L83.30-0006-01
12 Connector
| Remove/Install | ||
Danger! | Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning. Inhaling overheated refrigerant vapors may be toxic. Risk of injury. Contact with liquid refrigerant may result in injury to the skin and eyes. | Do not carry out any welding work on the closed air conditioning system or in the surrounding area. No smoking or open flames. Wear eye protection and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
Danger! | Risk of accident from vehicle starting off by itself when engine running. Risk of injury from bruises and burns if you place your hand into the engine when it is started or when it is running. | Secure vehicle to prevent it from moving off by itself. | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models fitted with air conditioning | |
| Notes on handling refrigerant R134a | All models with R134a refrigerant | |
1 | Discharge air conditioning system | ||
2 | Remove poly V-belt | Engine 602.984/985 | |
Engines 904.904/908/923 | |||
3 | Remove connector (12) | Mark connector (12). | |
4 | Disconnect refrigerant lines (8, 9) from screw-in pipe connections (6, 7) | 7/8" screw-in pipe connection, refrigerant compressor to refrigerant line | |
11/16" screw-in pipe connection, refrigerant compressor to refrigerant line | |||
5 | Unscrew bolts (10). | Bolt, refrigerant compressor to combination holder | |
6 | Remove refrigerant compressor (4) | Together with manifolds (2) and refrigerant lines (8, 9). | |
7 | Unscrew screws (1) | Bolt, manifold to connecting piece | |
8 | Remove manifold (2) | Installation: Install new sealing rings (3). | |
9 | Remove refrigerant compressor connecting piece (4) | ||
10.1 | Replace refrigerant compressor (4) | Follow-up work: | |
Remove expansion valves | |||
Total capacity | |||
10.2 | Reconditioning refrigerant compressor (4) | Follow-up work: | |
Remove refrigerant compressor cylinder roller bearing (4) | |||
Remove electromagnetic clutch | |||
Remove refrigerant compressor shaft seal (4) | |||
Total capacity | |||
11 | Replace receiver/drier | The fluid reservoir must be replaced whenever work is carried out in the air conditioning system. | |
12 | Install in the reverse order | ||
| Inspecting | ||
13 | Evacuate air conditioning system and check for leaks | ||
14.1 | Fill and top up air conditioning system (gaseous) | ||
14.2 | Fill air conditioning system (liquid) | ||
15 | Check function of air conditioning | Run engine at idling speed for about 5 minutes and check all the component functions which are of relevance for proper operation of the air conditioning system. | |
16 | Perform quick test on air conditioning system |
Air conditioning
Number | Designation | Models 667, | |
BA83.40-N-1002-01B | Bolt, manifold to connector | Nm | 23 |
BA83.40-N-1003-01B | Bolt, A/C compressor to combination bracket | Nm | 23 |
BA83.40-N-1004-01B | Pipe union 7/8", A/C compressor to refrigerant line | Nm | 33 (4) |
BA83.40-N-1005-01B | 11/16" screw-in pipe connection, refrigerant compressor to refrigerant line | Nm | 44 (4) |
Air conditioning system
참조 문서
- ah8330n000301a 냉매 R134a 취급 관련 지침
- ah8330n000501a 정비 작업 시 에어컨의 회로와 부품들을 습기로부터 보호하십시오.
- ar1322d1202b
- ar1322d1202d
- ar8330l1209a
- ar8330l1762a
- ar8330l1767a
- ar8330l1777a
- ar8330l1780a
- ar8330l5530a
- ar8330l6520a
- ar8330l7682a
- ar8330l7686a
- ar8355l1100a
- ar8355l5350a
- as0000z000501a 엔진이 작동 중인 상태에서 급발진에 의한 사고 위험 시동 또는 구동 중인 엔진 근처에서 작업할 때 차량에 부딪히거나 열에 의한 상해 위험
- as8300z000101a 밀폐된 에어컨에서 용접 작업이나 납땜 작업을 실행할 경우 발생할 수 있는 폭발 위험 과열된 냉매 증기의 흡입으로 인한 중독 위험 액체형 냉매와의 피부 및 안구 접촉에 의한 상�