AR83.30-L-1767A | Fill air conditioning system, replenish (gaseous) | 15.11.11 |
MODEL 667, 668, 670 with CODE (H03) Air conditioning in front end
L83.30-0002-06
Illustrated on model 668
1 Suction side testing and filling valve
2 Pressure-side testing and filling valve
Fill | |||
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models with air conditioning | |
| Notes on handling R134a refrigerant | All models with R134a refrigerant | |
1 | Evacuating air conditioning system, leak test | ||
2 | Connect extraction, reconditioning and filling unit to testing and filling valves (1, 2) | Observe operating instructions for evacuation, preparation and charging unit. | |
Air conditioner service unit R134a gotis://E_83_05.0 | |||
3 | Charge air conditioning system with refrigerant | Total filling capacity | |
4 | Switch off extraction, reconditioning and filling unit | Air conditioner service unit R134a gotis://E_83_05.0 | |
5 | Detach suction and pressure lines from testing and filling valves (1, 2) | ||
| Checking | ||
6 | Perform quick test on air conditioning system |