AR83.30-L-5530A | Remove/install expansion valve with coolant line | 12.7.10 |
MODEL 667, 668, 670 with CODE (H03) Air conditioning in front end
L83.30-0014-06
1 Defroster duct
2 Fresh and recirculated air duct
3 Footwell air duct
L83.30-0015-06
4 Bracket
L83.30-0016-06
5 Temperature sensor coupling
L83.30-0017-06
6 Threaded pipe connection 7/8"
7 Threaded pipe connection 3/4"
8 Evaporator
L83.30-0013-06
9 Nut
10 Hose clamp
11 Rubber grommet
12 Expansion valve
13 Refrigerant lines
14 Threaded pipe connection 11/16"
15 Fluid reservoir
16 Threaded pipe connection 5/8"
17 Bolt
18 Retaining bracket
| Remove/install | ||
Danger! | Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning from inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
Danger! | Risk of accident caused by vehicle starting off by itself when engine is running. Risk of injury from bruises and burns if you place your hand into the engine when it is started or when it is running. | Secure vehicle to prevent it from moving by itself. | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models fitted with air conditioning | |
| Notes on handling refrigerant R134a | All models with R134a refrigerant | |
1 | Discharge air conditioning system | ||
2 | Remove wiper arms | ||
3 | Remove front panel | ||
4 | Remove center section of instrument panel | ||
5 | Remove top part of instrument panel | ||
6 | Remove central electrical system fixture (4) | ||
7 | Pull defroster conduit (1) from heater housing | On left and right. | |
8 | Remove footwell air duct (3) | On left and right. | |
9 | Detach coupling (5) of temperature sensor | Mark connector (5). | |
10 | Remove fresh and recirculated air conduit (2) | On left and right. Installation: Ensure that lower area is sealed. | |
11 | Remove evaporator refrigerant lines (8) from threaded pipe connections (6, 7) | Installation: Replace sealing rings. | |
3/4" screw-in pipe connection, evaporator to refrigerant line | |||
7/8" screw-in pipe connection, evaporator to refrigerant line | |||
12 | Unscrew bolts (17) and nuts (9) | At the retaining brackets (18). | |
13 | Remove hose clamps (10) from refrigerant lines (13) | ||
14 | Remove refrigerant lines (13) from threaded pipe connections (14, 16) | Installation: Replace sealing rings. | |
Threaded pipe connection 5/8", fluid reservoir to expansion valve refrigerant line | |||
Threaded pipe connection 11/16", AC compressor to expansion valve refrigerant line | |||
15 | Remove expansion valves (12), refrigerant lines (13) with rubber grommets (11) upwards | Avoid damage. | |
Replenishing quantity when replacing refrigerant lines with expansion valves | |||
16 | Remove fluid reservoir (15) | The fluid reservoir (15) must be replaced every time you open up the air conditioning. | |
17 | Install in the reverse order | ||
| Checking | ||
18 | Evacuating air conditioning system, leak test | ||
19.1 | Fill air conditioning system, replenish (gaseous) | ||
19.2 | Fill air conditioning system (liquid) | ||
20 | Check function of air conditioning | Run engine at idling speed for about 5 minutes and check all the component functions which are of relevance for proper operation of the air conditioning system. | |
21 | Perform quick test on air conditioning system |
Automatic air conditioning
Number | Designation | Model 667, | |
BA83.40-N-1007-01B | Pipe union 3/4", evaporator core to refrigerant line | Nm | 45 (5) |
BA83.40-N-1008-01B | 7/8" screw-in pipe connection, evaporator to refrigerant line | Nm | 33 (4) |
BA83.40-N-1009-01B | Threaded pipe connection 5/8", fluid reservoir to | Nm | 17 (3) |
BA83.40-N-1010-01B | Threaded pipe connection 11/16", AC compressor to | Nm | 44 (4) |
Air conditioning
참조 문서
- ah8330n000301a 냉매 R134a 취급 관련 지침
- ah8330n000501a 정비 작업 시 에어컨의 회로와 부품들을 습기로부터 보호하십시오.
- ar6810d1020a
- ar6810d1030a
- ar8230l6100a
- ar8330l1209a
- ar8330l1762a
- ar8330l1767a
- ar8330l1777a
- ar8330l1780a
- ar8330l6520a
- ar8880l1000a
- as0000z000501a 엔진이 작동 중인 상태에서 급발진에 의한 사고 위험 시동 또는 구동 중인 엔진 근처에서 작업할 때 차량에 부딪히거나 열에 의한 상해 위험
- as8300z000101a 밀폐된 에어컨에서 용접 작업이나 납땜 작업을 실행할 경우 발생할 수 있는 폭발 위험 과열된 냉매 증기의 흡입으로 인한 중독 위험 액체형 냉매와의 피부 및 안구 접촉에 의한 상�