Check delivery rate of the fuel metering pump

種別 ar · トピック 83.70 · バージョン 0101 · 2019-03-14

適用: Model 906.1/2 with code H11 (Auxiliary hot-air heater) AIRTRONIC heater D2

「ja」では利用できません。英語で表示しています。

位置付け

機能グループ 3 ボディ › 83 クライメート・コントロール › 83.70 補助ヒータ、補助暖房、補足ヒータ — シリーズ 906(モデル 1**, 2**)

EinPAS 39 ヒータ/ベンチレーション/冷却 › 39.25 補助ヒータ/補助ヒータ › 39.25.46 ポンプ/リザーバ — シリーズ 906(モデル 1**, 2**)

AR83.70-D-1178F

Check delivery rate of the fuel metering pump

07.03.2019

Model

906.1/2

with code H11 (Auxiliary hot-air heater)

AIRTRONIC heater D2

Check delivery rate of the fuel metering pump

51

Tank-side fuel line

52

Metering pump holder

53

Pressure-side fuel line

Y23/5

Metering pump

D83.70-1432-11

Remove

Danger

Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel.

No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only.
Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

Topical note

Preconditions/notes regarding checking the delivery rate of the fuel metering pump

AH83.70-N-0002-01A

1

Remove tank-side fuel line (51) from metering pump (Y23/5)

2

Remove, clean and reinstall fuel strainer of metering pump (Y23/5)

3

Remove pressure-side fuel line (53) from metering pump (Y23/5)

4

Connect measuring hose to pressure side of metering pump (Y23/5) and insert end of measuring hose into a measuring glass

5

Connect multimeter for monitoring battery voltage to battery

To measure the delivery rate, a battery voltage of 11 V to 13 V must be present.

Bleeding

6

Switch on hot-air auxiliary heater

The fuel feed begins after approx. 1 minute. To bleed the fuel line, allow the heater to run until the fuel is discharged evenly and bubble-free at the measuring hose.

7

Switch off hot-air auxiliary heater

8

Empty measuring glass and insert end of measuring hose into measuring glass again

Measure

9

Switch on hot-air auxiliary heater

The fuel feed begins after approx. 1 minute. Hold the measuring glass level with the heater during measurement.

10

Wait for fuel delivery to stop

The auxiliary heater control unit stops delivering fuel after approx. 90 s.

11

Switch off hot-air auxiliary heater

12

Determine feed quantity in measuring glass and compare with specified values

Fuel delivery quantity in 90 s

*BE83.70-N-1001-04A

If the specified values are not reached:

Replace fuel metering pump


AR83.70-D-5652H

Install

13

Remove multimeter from battery

14

Detach measuring hose from metering pump (Y23/5) and reattach pressure-side fuel line (53)

Check values for fuel metering pump

Number

Designation

Model 901, 902, 903, 904, 905, 906
with code H11 (Auxiliary hot-air heater)
Heater unit D1L-C compact

Model 901, 902, 903, 904, 905, 906
with code H11 (Auxiliary hot-air heater)
Heater unit D3L-C compact

BE83.70-N-1001-04A

Fuel delivery quantity in 90 s

min

cm3

3,4

4,5

max

cm3

4,7

5,5

Check values for fuel metering pump

Number

Designation

Model 901, 902, 903, 904, 905, 906
with code H11 (Auxiliary hot-air heater)
Heater unit B3L-C compact

Model 901, 902, 903, 904, 905, 906
with code H11 (Auxiliary hot-air heater)
AIRTRONIC heater unit D2

BE83.70-N-1001-04A

Fuel delivery quantity in 90 s

min

cm3

9,5

3,7

max

cm3

11,5

4,3

Check values for fuel metering pump

Number

Designation

Model 901, 902, 903, 904, 905, 906
with code H11 (Auxiliary hot-air heater)
AIRTRONIC heater unit D4

Model 901, 902, 903, 904, 905, 906
with code H11 (Auxiliary hot-air heater)
Airtronic heater unit D4S

BE83.70-N-1001-04A

Fuel delivery quantity in 90 s

min

cm3

5,4

–

max

cm3

6,3

–