S83.55-4510-09
Shown on model 447 with transmission 722.9 |
1 | Refrigerant lines | 4 | Electrical connector | |
2 | Oil lines | 5 | Bolts | |
3 | Screw | 6 | Refrigerant compressor |
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R1234yf | |||
Notes on handling refrigerant R134a | |||
| Remove/install | ||
1 | Drain air conditioning system |
| |
Model 447 with code HX1 (R-1234yf refrigerant) | |||
2 | Remove air filter housing | ||
3 | Remove poly-V-belt from belt pulley of refrigerant compressor (6) | ||
4 | Unfasten coolant expansion reservoir and swivel out of working area with attached coolant hoses | ||
Do not extract coolant. | |||
5 | Remove refrigerant lines (1) from refrigerant compressor (6) | ||
| Compressor oils (specification 362.1) | ||
Installation: Replace sealing rings and moisten with compressor oil. | |||
Bolt, refrigerant line on refrigerant compressor | |||
6 | Seal openings on refrigerant lines (1) and at refrigerant compressor (6) using stop plugs | Record plug | |
7 | Remove screws (3) and remove oil lines (2) from refrigerant compressor (6) | Model 447 with engine 651 with transmission 722.9 | |
8 | Disconnect electrical connection (4) | ||
9 | Remove screws/bolts (5) | Bolt, A/C compressor to major assembly carrier | |
10 | Remove refrigerant compressor (6) | ||
11 | Install in the reverse order | ||
12 | Carry out breaking in of refrigerant compressor (6) using vehicle diagnosis system | When replacing the refrigerant compressor (6). | |
|
129 589 00 91 00
Record plug
Viitatut asiakirjat
- ad0000s200004e
- ah8330n000301a Ohjeita kylmäaineen R134a käsittelyyn
- ah8330n000501a Suojaa ilmastointilaitteen kylmäainekierto ja rakenneosat kosteudelta korjaustöiden ajaksi
- ah8330p000302a Huomautuksia kylmäaineen R1234yf käsittelyyn
- ar0910s1150e
- ar1322s1202e
- ar2030s4950e
- ar8330s1760e
- ar8330s1760ef
- as8300z000601a Myrkytysvaara: ilmastointilaitteen ylikuumentuneen kylmäaineen R134a höyryjen hengittäminen voi aiheuttaa myrkytyksen. Loukkaantumisvaara: nestemäinen kylmäaine R134a voi aiheuttaa iho- ja silmävammoja ja paineenalaisten osien
- as8300z000701a Palovaara: kylmäaineen R1234yf syttyminen kuumissa rakenneosissa voi aiheuttaa palovamman. Myrkytysvaara: Ilmastointilaitteen ylikuumentuneen kylmäaineen höyryt ovat terveydelle vaarallisia. Loukkaantumisvaara: ulos valunut kylmäaine
- bb0040p036201a