ar8330s6540e

Remove/install condenser

Tyyppi ar · aihe 83.30 · versio 0305 · 2019-04-19

Koskee: Model 447 with engine 274, 651 with code HH4 (THERMOTRONIC automatic climate control) Model 447 with engine 274, 651 with code HH9 (Air conditioner, automatic heater control) Model 448 with engine 274 with code HH4 (THERMOTRONIC automatic climate control)

Ei saatavilla kielellä ”fi”; näytetään kielellä Englanti.

Sijainti

Toimintoryhmä 3 Kori, päällysrakenne › 83 Lämmitys, tuuletus ja ilmastointi › 83.30 Ilmastointilaite — Mallisarja 447 · Mallisarja 448 · Mallisarja 651

EinPAS 39 Lämmitys/tuuletus/jäähdytys › 39.15 Ilmastointi › 39.15.41 Lauhdutin/kuivain/kaasunjäähdytin — Mallisarja 447 · Mallisarja 448 · Mallisarja 651

Koskee myös moottoreita/vaihteistoja: 274 ***

AR83.30-S-6540E

Remove/install condenser

12.04.2019

Model

447 with engine 274, 651

with code HH4 (THERMOTRONIC automatic climate control)

Model

447 with engine 274, 651

with code HH9 (Air conditioner, automatic heater control)

Model

448 with engine 274

with code HH4 (THERMOTRONIC automatic climate control)

Remove/install condenser

S83.30-4595-09

Shown on model 447 with transmission 722.9

1

Right air duct segment

5

Screw

8

Refrigerant lines

2

Left air duct segment

6

Catch hook

9

Condenser

3

Electrical connector

7

Nuts

10

Locks

4

Oil cooler

Remove/install condenser

S83.30-4651-09

Shown on model 447 with engine 274

11

Electrical connector

12

Lower air duct segment

13

Locks

Danger

Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated.

AS83.00-Z-0007-01A

Warning

Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts

Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated.

AS83.00-Z-0006-01A

Topical note

Protect air conditioning circuit and components from moisture when carrying out repair work

AH83.30-N-0005-01A

Notes on handling refrigerant R1234yf

AH83.30-P-0003-02A

Notes on handling refrigerant R134a

AH83.30-N-0003-01A

Remove/install

1

Drain air conditioning system


Model 447 except code HX1 (R-1234yf refrigerant), model 448

AR83.30-S-1760E

Model 447 with code HX1 (R-1234yf refrigerant)

AR83.30-S-1760EF

2

Remove cross member

AR62.30-S-1360E

3

Remove right air duct segment (1)

4

Unhook outside temperature sensor from left air duct segment (2)

Model 447 with engine 651

5

Remove left air duct segment (2)

6

Disconnect electrical connection (11)

Model 447, 448 with engine 274

7

Release locks (13) and remove lower air duct segment (12)

Model 447, 448 with engine 274

Installation: Make sure lower air duct segment (12) is correctly seated in guides (arrows).

8

Disconnect electrical connection (3)

9

Remove bolt (5)

Model 447, 448 with transmission 722.9

10

Release catch hook (6), unhook oil cooler (4) and swivel out of working area

Model 447, 448 with transmission 722.9

11

Unscrew nuts (7)

Nut, refrigerant line to refrigerant condenser

*BA83.30-N-1019-01A

12

Remove refrigerant lines (8) from condenser (9)

Compressor oils (specification 362.1)

BB00.40-P-0362-01A

Condenser with connection lines modified

Model 447 with engine 274, 651
with code HH4 (THERMOTRONIC automatic climate control)
Model 447 with engine 274, 651
with code HH9 (Air conditioner, automatic heater control)

BT83.30-S-0003-01E

Installation: Replace sealing rings and moisten with compressor fluid.

If refrigerant lines (8) in the previous version are mounted to a modified version condenser (9).

Remove cylinder pins from connection fittings of refrigerant lines (8).

13

Seal connection fittings on refrigerant lines (8) and on condenser (9) using stop plugs

Record plug

*129589009100

14

Release locks (10)

15

Remove condenser (9) downwards

16

Modify bracket of condenser (9)

When replacing the condenser (9).

17

Install in the reverse order

Air conditioning

Number

Designation

Model 447 with engine 274, 651
Model 448 with engine 274

BA83.30-N-1019-01A

Nut, refrigerant line to refrigerant condenser

Nm

12

Remove/install condenser

129 589 00 91 00

Record plug

Viitatut asiakirjat