Controlled heating mode function

Type gf · topic 83.70 · version 0101 · 2004-05-06

Applies to: MODELS 950, 952, 953, 954 with CODE (H60) Warm air heater "Eberspächer D1 LP" with CODE (H62) Warm air heater "Eberspächer D3 LP" MODELS 970, 972, 974, 975, 976 with CODE (H60) Warm air auxiliary heater "Eberspächer" D1 LP with CODE (H62) Warm air auxiliary heater "Eberspächer" D3 LP MODELS 375.4, 944 with CODE (H60) Warm air heater "Eberspächer D1 LP"'

Where it sits

Function group 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — Series 375 (models 4**) · Series 944 · Series 950 · Series 952 · Series 953 · Series 954 · Series 970 · Series 972 · Series 974 · Series 975 · Series 976

GF83.70-W-2004D

Controlled heating mode function

27.1.98

MODELS 950, 952, 953, 954
with CODE (H60) Warm air heater "Eberspächer D1 LP"
with CODE (H62) Warm air heater "Eberspächer D3 LP"

MODELS 970, 972, 974, 975, 976
with CODE (H60) Warm air auxiliary heater "Eberspächer" D1 LP
with CODE (H62) Warm air auxiliary heater "Eberspächer" D3 LP

MODELS 375.4, 944 with CODE (H60) Warm air heater "Eberspächer D1 LP"

Controlled heating mode function

W83.70-0142-09

1 Fuse

2 Warm air blower

3 Controller board with temperature sensor

4 Combustion air and heater blower

5 Combustion air blower

6 Glow plug

13 Fuel metering pump

14 Timer

A Fuel supply line

B Combustion air inlet

C Exhaust outlet

D Cold air inlet

E Warm air outlet

7 Overheating sensor

8 Burner insert

9 Flame sensor

10 Afterburner pipe

11 Heat exchanger

12 Jacket

Closed-loop operation

The temperature sensor integrated in the controller board (3) continuously measures the temperature of the drawn-in interior air and compares the measured value with the timer (14) specified value.

Control "LOW" - "MEDIUM" - "LOW":

The heater switches to the "LOW" control setting when the interior temperature exceeds the set temperature. The combustion air and heater blowers (4) run at their slowest speed. The fuel metering pump (13) is run at the slowest clock frequency

If the interior temperature drops below the specified temperature, the heater switches to the "Medium" control setting.

"LOW" - "MEDIUM" - "LOW" control usually covers all heating requirements.

If the heating requirement exceeds the heat provided by the "MEDIUM" setting, the heater switches to the "POWER" control setting.

If the heating requirement is less than the heat provided by the "LOW" setting, the heater switches to the "OFF" control setting.

Control interval

After the regulated heater power-down mode, constant ventilation at the lowest blower speed setting takes place.

If the interior temperature drops below the specified value a new starting procedure takes place.

The restart takes place at the "MEDIUM" control setting.

Heat exchanger, location/task/design

GF83.70-W-4017D

Glow plug, location/task

GF83.70-W-4013A

Flame sensor, location/task

GF83.70-W-4014A

Timer, location/task/design

GF83.70-W-4022C

Fuel metering pump, location/task/design

GF83.70-W-4023A

Overheating sensor, location/task/design

GF83.70-W-4025B

Combustion air and heater blower, location/task/design

GF83.70-W-4027C

Auxiliary heater controller board, location/task/design

GF83.70-W-4028C

Burner insert with afterburner pipe, location/task/design

GF83.70-W-4029C

Referenced documents