gf8340p2000e

Automatic air conditioning pushbutton control module position/function

Type gf · topic 83.40 · version 0103 · 2001-07-17

Applies to: MODEL 202 as of 1.9.95 with CODE (581a) Air conditioning (Automatic)

Where it sits

Function group 3 Body › 83 Climate control › 83.40 Air conditioning (automatic) — Series 202

GF83.40-P-2000E

Automatic air conditioning pushbutton control module position/function

5.12.97

MODEL 202 as of 1.9.95 with CODE (581a) Air conditioning (Automatic)

Automatic air conditioning pushbutton control module position/function

P83.40-2028-04

Automatic pushbutton

Warm temperature pushbutton

Cold temperature pushbutton

Defrost pushbutton

Recirculated air pushbutton

Air distributor pushbutton

Rest pushbutton

Blower pushbutton

EC pushbutton

N22 Air conditioning (Automatic) (Automatic) A / C pushbutton control module

Function

The control and operating module (N22) permits performance of adjustments required by the driver, such as:

Passenger compartment temperature selection by pressing the warm/cold pushbuttons ( , ), a separate adjustment for driver and passenger is not possible

Manual air quantity by pressing the pushbutton +/-

Manual air distribution by pressing the pushbutton

Recirculated air by pressing the pushbutton

Activation of residual engine heat recirculation, with ignition off, by pressing the

pushbutton

Switching off cooling by pressing the pushbutton

Automatic air distribution and blower speed by pressing the pushbutton

Defrosting function by pressing the pushbutton

The driver will be shown these adjustments on the display.

Furthermore the control module integrated into the control and operating (N22) module takes over regulation and control of systems, such as:

comparison of the preselected / actual temperatures and adjustment of the passenger compartment temperature

automatic switching from fresh air to recirculated air

automatic air distribution

automatic blower speed

actuation of the refrigerant compressor

actuation of the auxiliary ventilator

The control and operation module (N22) can be diagnosed so that faults arising are stored in a fault memory, which can be read out On Board or with the aid of the Hand-Held Tester.

When changing the control and operating module (N22) a variant coding should be performed with the aid of the Hand-Held Tester.

Blower pushbutton Location/task/function

GF83.40-P-2144A

Air distribution pushbutton Location/task/function

GF83.40-P-2159A

Recirculated air pushbutton Location/task/function

GF83.40-P-2145A

EC pushbutton Location/task/function

GF83.40-P-2146E

Warm temperature pushbutton Location/task/function

GF83.40-P-2160A

Automatic pushbutton Location/task/function

GF83.40-P-2147E

Rest pushbutton Location/task/function

GF83.40-P-2148A

Cold temperature pushbutton Location/task/function

GF83.40-P-2161A

Defrost pushbutton Location/task/function

GF83.40-P-2139A

Display Location/task/function

GF83.40-P-2150A

Referenced documents