gf8235p3003pp

Washer nozzles/washer nozzle hose heater, function

Type gf · topic 82.35 · version 0101 · 2004-03-10

Applies to: MODELS 203.0 /2 /7 up to 23.4.04 with CODE (875) Heated windshield washer system

Where it sits

Function group 3 Body › 82 Electrical system, body › 82.35 Windshield washing system — Series 203 (models 0**, 2**, 7**)

GF82.35-P-3003PP

Washer nozzles/washer nozzle hose heater, function

3.12.99

MODELS 203.0 /2 /7 up to 23.4.04 with CODE (875) Heated windshield washer system

Washer nozzles/washer nozzle hose heater, function

P82.35-2337-06

B14 Ambient temperature display temperature sensor

G2 Alternator

N10/1 Front SAM control unit with fuse and relay module

N73 DI control unit

R2/1 Washer nozzle heater

R2/11 Washer nozzle hose heater

CAN-B Controller area network bus class B (interior compartment) (CAN B)

Washer nozzles and washer nozzle hose heaters, function

The washer nozzle heaters (R2/1) and washer nozzle hose heaters (R2/11) are switched on automatically when:

Circuit 61 on (engine: on) and

an outside temperature of less than 5 °C is detected.

Switch off is accomplished automatically when:

Circuit 61 off (engine: off) or

an outside temperature greater than 8 °C is detected.

If the values are missing or implausible (outside temperature, circuit 61) the washer nozzle heater (R2/1) and the

washer nozzle hose heater (R2/11) are not actuated.

Actuation of heating elements

The heating elements of the washer nozzle heater (R2/1) and the washer nozzle hose heater (R2/11) are switched in parallel.

The washer nozzle heater (R2/1) and the washer nozzle hose heater (R2/11) are actuated directly by the front SAM control unit with fuse and relay module (N10/1). In this case, the front SAM control unit with fuse and relay module (N10/1) switches term. 30 onto the heating elements.

Required data

The outside temperature is recorded by the outside temperature indicator temperature sensor (B14). The front SAM control unit with fuse and relay module (N10/1) directly reads in the sensor.

The status of circuit 61 of the alternator (G2) is read in directly by the front SAM control unit with fuse and relay module (N10/1).