gf6739p2001gd

Overload protection, function

Type gf · topic 67.39 · version 0100 · 1997-07-09

Applies to: MODEL 168 with CODE (236) Power windows (front and rear doors)

Where it sits

Function group 3 Body › 67 Windows › 67.39 Electric side windows — Series 168

GF67.39-P-2001GD

Overload protection, function

26.3.97

MODEL 168 with CODE (236) Power windows (front and rear doors)

The power window motors are protected against an overload by

a lockup recognition and

a software heat protection feature

programmed into each door control module
(N69/1, N69/2, N69/3, N69/4).

Lock-up recognition

Two hall sensors are located on each power window motor allowing the corresponding door control module to recognize the rotary motion of the motor.
If a power window switch is pressed and the door control module does not recognize the rotary motion, the power window motor is switched off after approx. 0.5 s.

Software heat protection feature

The door control modules calculate the temperature of the associated power window motor.
After reaching the switch-off threshold the function presently being performed is completed and actuation of the power window motor is then interrupted.

When the door control reaches the switch-off threshold during the "Pinch protection" function, this is ignored until the return procedure is completed.

Door control module, location/purpose/design

with code 236 "Power windows
(front and rear doors)"

GF67.39-P-3101GC

Referenced documents