ME-SFI alternator interface function

Type gf · topic 07.61 · version 0100 · 2008-04-01

Applies to: ENGINE 271.954 in MODEL 171.445 as of Model Year 09 / AEJ 08 model refinement package

Where it sits

Function group 1 Engine › 07 Mixture formation › 07.61 ME fuel injection/ ignition system — Series 171 (models 445)

Also applies to engines/gearboxes: 271 954

GF07.61-P-3003MFK

ME-SFI alternator interface function

22.2.08

ENGINE 271.954 in MODEL 171.445 as of Model Year 09 / AEJ 08 model refinement package

Function requirements for the alternator interface, general points

Circuit 87M ON (engine control ON)

Engine running

Alternator interface, general points

Through the alternator interface, messages are exchanged over the drive LIN (LIN C1) between the alternator (G2) and the ME-SFI control unit (N3/10), and the alternator control response is controlled.

For this purpose, the ME-SFI control unit reads the following sensor and signal:

- Crankshaft position sensor (L5), motor speed

- Battery voltage (G1) through "tml. 30"

Alternator interface function sequence

The ME-SFI control unit sets the control response of the alternator, for example, in order to lower the regulation voltage (charging voltage) at idle when the battery is sufficiently charged. This reduces engine load, thus also reducing fuel consumption and improving exhaust gas emissions.

-----------------------------------------------------------------------------------------

The ME-SFI control unit controls the following functions:

- Switching on the alternator after engine start.

- Regulation of the alternator according to performance maps stored in the ME-SFI [ME] control unit. To do this, the control voltage is preset by the ME-SFI [ME] control unit.

- Adapting the control voltage with a delay in the event of frequent load changes at the alternator to stabilize the idling speed.

- Protecting the alternator against overheating.

- Generating a "circuit 61 signal" (alternator in function).

- Reporting detected faults to the instrument cluster (A1) for actuation of the respective warning lamps and display messages.

The alternator constantly performs self-diagnosis and sends the results when requested to the ME-SFI [ME] control unit. This control unit compares the results with other signals (for example, engine speed, battery voltage, time since engine start) in order to detect faults in the alternator.

-----------------------------------------------------------------------------------------

The following faults are identified:

- Short circuit or discontinuity at output "terminal 61" from ME-SFI [ME] control unit.

- Open circuit on alternator interface line (drive LIN) or interface driver fault in the ME-SFI control unit. For this type of fault, a regulation voltage of 13.45 up to 14.15 V is given.

- Electrical and mechanical faults at alternator:
- controller or diodes defective
- stator interruption or short circuit
- exciter interruption
- regulation voltage and charging current not reached
- regulation voltage too high
- cracked or loose poly-V belt

Diagnosis

To check the regulation voltage, the battery must be loaded with a battery tester, as the regulation voltage can be significantly reduced when the battery is fully charged and under no load.

"Terminal 61 signal"

For alternators with an alternator interface, line
"terminal 61" is not needed. From information which the ME-SFI [ME] control unit receives via the alternator interface, the "terminal 61 signal" is simulated in the ME-SFI [ME] control unit and is emitted via an output stage switching to ground (e.g. for the instrument cluster).

Electrical function schematic, alternator interface ME

PE07.61-P-2755-97TB

ME-SFI [ME] control unit, component description

N3/10

GF07.61-P-6000MFK

Crankshaft position sensor, component description

L5

GF07.04-P-6010MFK

Referenced documents