1 | Screw |
2 | Linkage rod |
3 | Linkage rod |
4 | Electrical connector |
M16/21 | Fresh air/air recirculation flap actuator motor |
N83.10-2035-11
| Remove/install | ||
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Topical note | General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system | ||
1 | Remove center stowage compartment | ||
2 | Remove screw/bolt (1) | ||
3 | Unhook linkage (2) | ||
4 | Unhook linkage (3) | ||
5 | Disconnect electrical connector (4) from fresh air and air recirculation flap actuator motor (M16/21) | ||
6 | Remove fresh air and air recirculation flap actuator motor (M16/21) | Unclip fresh air and air recirculation flap actuator motor (M16/21). | |
7 | Install in the reverse order | ||
| Check | ||
8 | Perform function check on fresh air and air recirculation flap actuator motor (M16/21) | Switch on ignition, operate blower switch and check ventilation nozzles for correct operation. |
Referenced documents
- ah0000z030001a General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment
- ar6810s1620s Remove/install center stowage compartment
- as0000z003501a Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC)