AR20.40-T-0001AA | Remove/install hydraulic | 6.6.01 |
ENGINE 457.942 in MODEL NMB671.020 /021 /030 /042 /333
T20.40-0009-01
1 Hydraulic motor
2 Leak oil line
3 Return flow pipe
4 Pressure line
5 Fan
6 Retaining frame
7 Adapter piece
8 Proportioning valve
| Remove/Install | ||
1 | Remove radiator unit | ||
2 | Detach the leak oil line (2) from the hydraulic motor (1) | Installation: Install new sealing rings. | |
3 | Remove the return line (3) between the hydraulic motor (1) and the adapter piece (7) | Collect hydraulic oil which flows out in a suitable vessel. | |
Installation: Clean sealing surfaces and install new sealing rings. | |||
4 | Remove the pressure line (4) between the hydraulic motor (1) and the proportioning valve (8) | Collect hydraulic oil which flows out in a suitable vessel. | |
Installation: Clean sealing surfaces and install new sealing rings. | |||
5 | Detach the hydraulic motor (1) from the retaining frame (6) | ||
6 | Detach the fan (5) | The fan (5) is screwed on to the tapering shaft of the hydraulic motor (1). To detach the fan (5), the connection must be removed . | |
7 | Install in the reverse order |
Referenced documents
- ar2020t3871aa Remove/install radiator unit
- ar2020t3871aaa Remove/install radiator unit
- ar2040t5614aa Remove/install fan