1 | Sensor |
2 | Fastening bolt |
3 | Sensor |
4 | Ignition coil assembly |
5 | Plug cables |
B15.10-0007-11
| Remove/install | ||
Danger | Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves when emptying gas cylinders. Risk of poisoning or suffocation caused by inhaling gas. | Remove any sources of ignition. | |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
1 | Disconnect the battery negative cable or turn-off the master switch. | ||
2 | Loosen the sensors (1) and (3) from the ignition coil assembly (4). | ||
3 | Disconnect the plug cables (5). | ||
| |||
Observe spark plug cables for correct installation. | |||
Check spark plug cables for possible damage, if necessary replace them. | |||
4 | Loosen the attachment bolts (2) and remove the ignition coil assembly (5). | Fastening of the ignition coil | |
5 | Install in reverse order. |
Referenced documents
- as0000z001801a Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves
- as0000z003501a Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC)
- gf1510b310201a Ignition coils, location