ar1440d2017ad

Remove/install pressure overflow valve at air controller unit of the exhaust aftertreatment system

Type ar · topic 14.40 · version 0100 · 2012-05-15

Applies to: ENGINES 900.9 in MODEL 668, 670 with CODE (MS2) BlueTec 5 (Euro 5)

Where it sits

Function group 1 Engine › 14 Exhaust manifold, engine brake, emission control system › 14.40 Exhaust aftertreatment, AdBlue — Series 668 · Series 670 · Series 900 (models 9**)

EinPAS 15 Engine › 15.40 Exhaust system/exhaust aftertreatment › 15.40.13 Line/hose/valve — Series 668 · Series 670 · Series 900 (models 9**)

AR14.40-D-2017AD

Remove/install pressure overflow valve at air controller unit of the exhaust aftertreatment system

4.5.12

ENGINES 900.9 in MODEL 668, 670 with CODE (MS2) BlueTec 5 (Euro 5)

Remove/install pressure overflow valve at air controller unit of the exhaust    
	aftertreatment system

D14.40-0152-06

1 Electrical connector

2 Screw/bolts

3 Compressed-air line

4 Compressed-air line

5 Connection fitting

6 Overflow valve

7 Nut

8 Connection fitting

Remove/install

Notes on compressed air connection systems

AH00.18-N-0001-01A

1

Switch off ignition

Air lines have compressed air applied to them for up to 3 min after the engine by the EATS. It is only after this that work can be begun on the EATS.

2

Disconnect electrical connection (1) from SCR compressed air pressure limiter solenoid valve

3

Remove screw/bolts (2)

*BA14.40-N-1015-02E

4

Unfasten air line (3) by about 2 revolutions and relieve pressure, then completely remove air line (3) completely

Installation: Replace O-ring on the air line (3).

*BA14.40-N-1019-02E

5

Unfasten air line (4) by about 2 revolutions and relieve pressure, then completely remove air line (4) completely

Installation: Replace O-ring on the air line (4).

*BA14.40-N-1019-02E

6

Unscrew connection fitting (5) from overflow valve (6)

*BA14.40-N-1018-02E

7

Remove overflow valve (6) together with SCR compressed air pressure limiter solenoid valve

8

Loosen nut (7) and remove connection fitting (8) from overflow valve (6)

Only when replacing the overflow valve (6).

Installation: Take note of the direction of installation (arrow) on the overflow valve (6) housing.

*BA14.40-N-1020-02E

9

Install in the reverse order

10

Fill compressed air system up to the shutoff pressure and check for leaktightness

Exhaust aftertreatment, Blue Tec

Number

Designation

Engine
900.9
in model
668, 670

BA14.40-N-1015-02E

SCR air pressure limiter solenoid valve on bracket

Nm

20

BA14.40-N-1018-02E

Check valve connection fitting on bracket

Nm

40

BA14.40-N-1019-02E

Compressed air connecting line to check valve connection fitting

Nm

10

BA14.40-N-1020-02E

Nut, compressed air connection fitting for SCR air pressure limiter solenoid valve to check valve

M22

Nm

40

Referenced documents