1 | Switchover valve |
2 | Electrical connector |
3 | Nuts |
4 | Connection fitting |
5 | Connection fitting |
6 | Connection fitting |
7 | Electrical connector |
D08.50-A043-76
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Warning | Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. | |
Topical note | General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system | ||
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
| Remove/install | ||
1 | Drain coolant of the auxiliary circuit. | ||
2 | Remove ventilation box. | ||
3 | Remove nuts (3). | ||
Topical note | Notes on self-locking nuts and bolts | ||
4 | Disconnect electrical connection (2). | ||
5 | Remove connection fitting (4) of the coolant line from the switchover valve (1). | ||
Collect escaping coolant. Seal connection fitting (4). | |||
Commercially available devices/tools | |||
Set of protective covers | |||
6 | Remove connection fitting (5) of the coolant line from the switchover valve (1). | ||
Collect escaping coolant. Seal connection fitting (5). | |||
Commercially available devices/tools | |||
Set of protective covers | |||
7 | Remove connection fitting (6) of the coolant line from the switchover valve (1). | ||
Collect escaping coolant. Seal connection fitting (6). | |||
Commercially available devices/tools | |||
Set of protective covers | |||
8 | Remove switchover valve (1) until the electrical connector (7) is accessible. | ||
9 | Remove the switchover valve (1). | For this purpose, disconnect electrical connector (7). | |
10 | Install in the reverse order. |
001 589 01 91 00
Set of protective covers
Referenced documents
- ah0000n000101a Notes on self-locking nuts and bolts
- ah0000p500001a Notes on avoiding damage through contamination and foreign objects
- ah0000z030001a General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment
- ah5400p000101a Information on preventing damage to electronic components due to electrostatic discharge
- ar0850d0022te Drain/fill coolant of auxiliary circuit
- ar0850p001801eq Open/close coolant hose coupling
- ar8310d0010ts Removing, installing ventilation housing
- as0000z003501a Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC)