D08.50-A035-79
1 | Expansion valve | 4 | Refrigerant line | 6 | Electrical connector | ||
3 | Electrical connector | 5 | Refrigerant line | 7 | Pressure and temperature sensor |
D08.50-A036-78
1 | Expansion valve | 9 | Bolts | 10 | Sealing rings | ||
7 | Pressure and temperature sensor |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | General information on handling vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
| Remove/install | ||
1 | Remove voltage of high-voltage on-board electrical system. | ||
2 | Drain refrigerant circuit. | ||
3 | Switch off ignition and store transmitter key outside of transmission range (min. 2 m). | ||
4 | Disconnect electrical connector (6) at pressure and temperature sensor (7). | ||
5 | Disconnect electrical connector (3). | ||
6 | Remove refrigerant line (5) from expansion valve (1). | ||
Seal refrigerant line (5). | |||
Record plug | |||
7 | Remove refrigerant line (4) from expansion valve (1). | ||
Seal refrigerant line (4). | |||
Record plug | |||
8 | Remove screws (9). | Screw, expansion valve for high-voltage battery cooling system to heat exchanger for high-voltage battery cooling system | |
9 | Remove expansion valve (1). | ||
| Compressor oils (specification 362.1) | ||
Plug openings. | |||
Installation: Install new sealing rings (10) and coat with compressor oil. | |||
Record plug | |||
10 | Install in the reverse order. |
129 589 00 91 00
Record plug
Referenced documents
- ah0000z030001a General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment
- ah8330n000301a Notes on handling refrigerant R134a
- ah8330n000401a Procedure for a damaged or leaky air conditioning system
- ah8330n000501a Protect air conditioning circuit and components from moisture when carrying out repair work
- ar4770d1000te Deenergize high-voltage on-board electrical system/put high-voltage on-board electrical system into operation
- ar8330d1760ts Drain, evacuate and recharge air conditioning, check for proper operation and check for leaks
- ar8330d7841te Remove/install refrigerant line between heat exchanger expansion valve and refrigerant condenser
- ar8330d7842te Remove/install refrigerant line between heat exchanger expansion valve and refrigerant compressor
- as0000z003501a Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC)
- as8300z000601a Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts
- bb0040p036201a Compressor oils (specification 362.1)