1 | Cap |
2 | Coolant expansion reservoir |
3 | Maintenance flap |
P20.00-2337-11
Danger ! | Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. | |
| Remove | ||
1 | Remove maintenance flap (3) | ||
2 | Screw down cap (1) | Turn cap (1) on coolant expansion reservoir (2) a half turn counterclockwise, release pressure and then screw down cap (1). | |
| Check | ||
3 | Check coolant level | ||
| Notes on coolant | ||
When the coolant is cold, the level must reach as far as the short marker bar in the filler opening; when warm, the coolant is approx. 1.5 cm higher. | |||
If coolant level is too low: | |||
| |||
Check cooling system for leaks subject to a separate repair order. | |||
4 | Check anticorrosion/antifreeze agent in coolant and enter in the maintenance sheet | ||
| Notes on coolant | ||
| Anticorrosion/antifreeze agents (Sheet 325.0) | ||
Antifreeze spindle | |||
If the anticorrosion/antifreeze content is too low: | |||
| |||
Correct anticorrosion/antifreeze content in coolant, subject to separate repair order. | |||
| Install | ||
5 | Seal coolant expansion reservoir (2) with cap (1) | ||
6 | Install maintenance flap (3) |
450 589 01 21 00
Antifreeze spindle
Referenced documents
- ah2000n208001a Notes on coolant
- as2000z000101a Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant.
- bb0040p032500a Anticorrosion/antifreeze agents (Sheet 325.0)