Test sheet of gas system for gas-operated installation units

Type ap · topic 00.10 · version 0101 · 2006-11-21

Applies to: MODEL WDF639.813 with ENGINE 646.980 /982, 112.951 /976, 642.990 with CODE (ZK7) "Marco Polo" camper Dokument nur gültig für China'

Where it sits

Function group 0 Overall › 00 Overall vehicle › 00.10 Complete vehicle, technical data, tests required by law — Series 639 (models 813) · Series 646 (models 980, 982)

EinPAS 10 Service › 10.20 Statutory inspections/legal requirements › 10.20.30 Tests — Series 639 (models 813) · Series 646 (models 980, 982)

EinPAS 45 Data/information › 45.10 Overall vehicle › 45.10.20 Overall vehicle — Series 639 (models 813) · Series 646 (models 980, 982)

Also applies to engines/gearboxes: 112 951, 112 976, 642 990

AP00.10-S-0001C

Test sheet of gas system for gas-operated installation units

5.12.05

MODEL WDF639.813 with ENGINE 646.980 /982, 112.951 /976, 642.990 with CODE (ZK7) "Marco Polo" camper
Dokument nur gültig für China

"Marco Polo" camper body

Test operation on gas system

Customer: Order number: License number:

Confirm that work has been completed by signing Inspector: Date:

Note: Carrying out the test work is to be confirmed in the Supplementary Instructions for the Fun/Marco Polo

Completed

Operation

Position no..

Test operation on gas system

Initial test

Recording the vehicle data

Check the first test date

Visual tests, condition tests and function tests

Bottle setting-up room

Gas cylinder model YSP-2 present

Yes no, not OK

AR00.10-S-0003C

Ventilation present,

unlockable

Yes no, not OK

No ignition sources present

Yes no, not OK

Warning information present and legible

Yes no, not OK

Pressure control unit

Operating pressure of complete system

tuned to 30 mbar

Yes no, not OK

AR00.10-S-0006C

Operation pressure information plate (adhesive label)

present and legible

Yes no, not OK

Safety devices against

unacceptabe pressure

Yes no, not OK

Condition and function faultless

Yes no, not OK

- When replacing:

- Manufacturer:

- Year of construction:

- no.:

- Output pressure:

Hose/pipelines

Hose line of the pressure class "PB6"

fitted in a length of 40 cm

Yes no, not OK

AR00.10-S-0002C

Condition faultless,

Yes no, not OK

- When replacing:

- Year of manufacture:

- Pressure class:

- Length:

Pipelines, outside diameter 8 mm

FITTED

Yes no, not OK

Condition faultless,

Yes no, not OK

Unit connection

Connection with

Hose/pipeline

Yes no, not OK

Unit shutoff devices

(quick-action valves)

- upstream of the units in each case

Condition and function faultless

Yes no, not OK

Operating instructions (adhesive label) of the unit shutoff devices

(quick-action valves) present and legible

Yes no, not OK

Cooker

Unit nominal connection pressure corresponds to an operating pressure of system of 30 mbar

Yes no, not OK

AR00.10-S-0005C

Cooker fitted:

Manufacturer:

(series production: Cramer SR s.r.o.)

Output:

(series production: 3.2 kW)

CE product ID:

(series production: 0085 AU 0118)

Warning information present and legible

Yes no, not OK

Flame panels not detachable

Yes no, not OK

Heat insulation present for building/equipment parts-

Yes no, not OK

Comments:

CONFIRMED

Test confirmations

Visual inspection has been carried out

The leaktightness test has been

performed

Test pressure: 150 mbar

Test medium: Air

System sealed Yes No

The combustion specimen and function of the ignition safeguarding device has been carried out/checked on the cooker

Yes no, not OK

The function test of the shutoff devices and pressure control unit has been carried out

Yes no, not OK

Specialist's findings/comments

CONFIRMED

Test result

The liquified gas system including the exhaust gas routings and the combustion air feeds are in proper condition as per the result of the test. The conditions for continued operation are met

The conditions for continued operation are not met in the event of changes to the liquified gas system .

The confirmation of the gas test is to be entered in the Fun/Marco Polo Supplementary Instructions.

The liquified gas system does not correspond to the requirements set as part of the test.? The conditions for continued operation are not met. A danger exists due to safety defects during winter operation. A new check is required

Completed

A copy of this test sheet for the gas system for natural-gas operated installation units is enclosed with the vehicle documents, gas check confirmed in the Fun/Marco Polo Supplementary Instructions

Next repeat test after 2 years have elapsed

Next test date:

Referenced documents