1 | Organizer bag |
2 | Rotating cabinet |
N00.10-2554-11
3 | Cover |
4 | Quick-release couplings |
5 | Valve |
6 | Pressure regulator |
7 | Hose line |
N00.10-2567-06
N00.10-2570-08
8 | Gas shut-off cock | 9 | Pipeline |
Danger ! | Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves when emptying gas cylinders. Risk of poisoning or suffocation caused by inhaling gas. | Remove any sources of ignition. | |
| Remove/install | ||
1 | Remove organizer bag (1) | ||
2 | Fold up rotating cabinet (2) | ||
3 | Remove cover (3) | Do this by opening the quick-release fittings (4). | |
Installation: Check for correct installation position of cover (3). | |||
4 | Close valve (5) | ||
5 | Unscrew hose line (7) from pressure regulator (6) | Threaded connection is a left-hand thread. | |
6 | Remove drawer under cooker | ||
7 | Open gas shut-off cock (8) | ||
8 | Close valves of cooker | ||
9 | Connect leak tester to hose line (7) | ||
| Check | ||
10 | Visually inspect hose line (7) and piping (9) | | |
The pressure class "PB6" and the manufacturing date are printed onto the hose line (7). | |||
Use genuine MB parts only. | |||
11 | Pressurize hose line (7) and piping (9) using leak tester at 150 mbar | The hose line (7) and piping (9) are checked at a pressure of 150 mbar. | |
After a waiting time of 5 minutes the pressure is read off, after another 5 minutes the measured pressure may drop by a maximum of 10 mbar. | |||
If the pressure drop is greater than 10 mbar | |||
| |||
Use suitable leak detector to localize the leak and rectify it, then repeat the test | |||
12 | Install in the reverse order |
Referenced documents
- ar8660s0020s Remove/install drawer
- as0000z001801a Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves