AD80.20-L-6001-59A | CL test of electrical system left side hinged door lock |
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | Locking left side hinged door Interior door lock microswitch |
10 | A8 |
15 | Connector disconnected from control module A8. Open door and engage exterior door lock latch |
< 5 Ω 5 Ω |
1.1 Adjust microswitch and carry out function check |
1.1 | Actuator microswitch |
10 | A8 |
15 | Connector disconnected from control module A8. Open door and engage exterior door lock latch. Engage locking button |
< 5 Ω 5 Ω |
1.2 Replace interior door lock |
1.2 | Actuator |
11 10 | A8 |
10 11 | Connector disconnected from control module A8. Open door and engage exterior door lock latch. Engage locking button | Locking button: Raises/lowers Does not move |
Replace CL control module (A8) Replace interior door lock |
Referenced documents
- ad8020l3001a Central locking (CL) diagnosis operational check
- ar8020l0101a Adjusting central locking microswitch
- ar8020l1922a Removing and installing central locking control module