AR80.20-L-0101A | Adjusting central locking microswitch | 31.5.99 |
MODEL 667, 668, 670 with CODE (FZ0) Central locking with master key
D80.20-0011-11
1 Inner door lock
2 Outer door lock
3 Screw
4 Microswitch
5 Screw
6 Latch
| Procedure applies for all doors | ||
1 | Remove inner door lock | Disconnect connector, unclip door linkage and remove outer door lock. | |
2 | Install inner door lock (1) on outer door lock (2) | Use original screws. | |
3 | Catch latch (6) into outer door lock (2) | ||
4 | Connect multimeter to microswitch contacts (4) for continuity check | Hinged door connector: black (sw) and yellow/black (ge/sw) Sliding/rear wall door connector: white/red (ws/rt) and green/black (gn/sw) | |
5 | Loosen screw (5) and adjust microswitch (4), tighten screw (5) | Hinged door 5 Ω. Sliding/rear wall door <5 Ω. | |
6 | Install in opposite order |
Commercially available tools