ad8020l3001a

Central locking (CL) diagnosis operational check

Type ad · topic 80.20 · version 0100 · 2003-06-12

Applies to: MODEL 667, 668, 670 with CODE (FZ0) Central locking with master key

Where it sits

Function group 3 Body › 80 Central locking system, convenience operation, drive authorization systems › 80.20 Central locking system, interior central locking — Series 667 · Series 668 · Series 670

AD80.20-L-3001A

Central locking (CL) diagnosis operational check

18.5.99

MODEL 667, 668, 670 with CODE (FZ0) Central locking with master key

Central locking (CL) diagnosis, previous knowledge

AD80.20-L-2001A

Battery voltage in order

The electrical system is checked in accordance with the Operating Instructions and is in order

Door openers and locking buttons must be easy to operate

Function check

Scope of test

Operation/Requirement

Result

Possible cause/Remedy

Central locking

Close all doors.

Operate the central locking in sequence, starting from each door (locking/unlocking) and check whether the doors are locked or unlocked

Locking buttons lower after locking is complete

Locking buttons spring up after locking is complete

End of test

Repeat locking doors within 5 seconds

Locking buttons lower after each time the doors with no faults are locked

Locking buttons spring up again after locking is complete

End of test

- Left cab hinged door

AD80.20-L-6001-57A

- Right cab hinged door

AD80.20-L-6001-58A

- Left side hinged door

AD80.20-L-6001-59A

- Right side hinged door

AD80.20-L-6001-60A

- Sliding door

AD80.20-L-6001-61A

- Rear door

Smear contact plates with pressure-sensitive paint, close door and open

again

- Contact pins touch the contact plates

AD80.20-L-6001-61A

- Contact pin impressions outside the contact plate

Check adjustment of door and door lock and adjust if necessary

Referenced documents