07.1-112 Checking start of delivery with digital tester (RIV method)
Job no. of Job Texts and Work Units or Standard Texts and Flat Rates 07-8244 and 8245 |
Unscrew screw plug (arrow) from governor |
unscrew. |
Testers (001, 017, 021) | connect, disconnect. |
Run engine at idle speed | read RI value off digital tester at 15° ATDC.
|
Special tools
Commercially available tools
Use without adapter | |
Digital testers | e. g. AVL, Diesel-Tester 873 |
e. g. Bosch, ETD 019.02 | |
e. g. Sun, DIT 9100 | |
Use with adapter | |
Digital tester | e. g. Bosch, MOT 103, 002.02, 250, 301 Hermann D960, D980 Bear DEACE Sun MEA 1500 |
Connection diagram for existing testers with adapter
017 | RI sensor |
021 | TDC pulse generator |
2 | Governor |
2i | RI sensor pin |
59 | TDC sensor pin |
001 | Digital tester |
010 | Adapter |
011 | Crocodile clamp |
015 | Test cable with plug |
016 | Diagnostic socket |
Checking
-------------------------------
1 Unscrew screw plug (11) from governor housing.
2 Turn RI sensor (017) into governor (injection pump).
3 Turn TDC pulse generator (021) into bracket (engine).
4 Connect digital tester according to connection diagram.
5 Engine idling. Read RI value (indirect start of delivery) off digital tester at idle speed.
RI set value: 15°1° ATDC.
Vehicles with code 62/0 14°+0.5° ATDC.
6 Switch off engine.
7 Disconnect digital tester.
8 Install screw plug in governor (tightening torque 30-35 Nm).
9 Carry out leak test with engine running.
10 Check engine oil level and correct, if required.
Henviste dokumenter
- ra07016010001x
- ra07016010002x
- ra07016010003x
- ra07016010116x
- ra07016010117x
- ra0701601a010x
- ra0701601a015x
- ra0701601b010x
- ra0701601b015x
- ra0701601c010x
- ra0701601c015x
- ra0701601d010x
- ra0701601e010x
- ra0701601f010x
- ra0701601g010x
- ra0701601h010x
- ra0701601i010x
- ra0701601j010x
- ra0701601k010x
- ra0701601l010x
- ra0701601m010x
- ra0701601n010x
- ra0701601o010x
- ra0701601p010x
- ra0701601pr02x
- ra0701601q010x
- ra0701601r010x
- ra0701601ta00x