GF83.70-P-3012B | Voltage too low or too high during heating mode, function | 10.7.97 |
MODEL 129 as of 1.6.97 with CODE (228) Stationary heater
P83.70-0393-09
1 Burner housing
2 Heat exchanger
3 Heater circuit thermostat
A6m1 Coolant circulation pump
Y23 Fuel metering pump
B Thermostat setting, open auxiliary circuit
A6m2 Combustion air blower
A6n1 Stationary heater/heater booster control module
N34 Stationary heater timer
Function sequence
1 Coolant temperature:> 59 °C :
The thermostat (3) is switched to heating mode, the stationary heater auxiliary circuit is connected to the cooling and heater circuit of the vehicle.
2 The heater operates at partial load or full load.
3 The stationary heater control module (A6n1) monitors the power supply to the stationary heater.
4 The control module recognizes a malfunction in the power supply:
The voltage is < 10.0 - 10.5 V for more than 20 s. The control module starts a malfunction switch-off to protect the battery from being discharged.
The voltage exceeds 15.5 V for more than 6 s. The control module starts a malfunction switch-off to protect the electric and electronic heater components.
5 The fuel metering pump (Y23) switches off thereby interrupting the combustion.
6 The actuation of the vehicle blower is interrupted and the blower is switched off.
7 The heater malfunction shut-off delay for cooling the heater and for purging the combustion chamber starts for approx. 110 s. The combustion air blower reduces its speed during the first 40 s of the shut-off delay to partial load operation and then increases again to almost full load operation.
8 The heater shut-off delay is terminated. The combustion air blower and the coolant circulation pump (A6m1) are switched off.
To reset switch heater on and off again after eliminating the cause of the malfunction.
| Burner housing, location/purpose/design | ||
| Heat exchanger, location/purpose/design | ||
| Stationary heater/heater booster control module, location/purpose | ||
| Coolant circulation pump, location/purpose | ||
| Combustion air blower, location/purpose | ||
| Stationary heater timer, location/purpose/function | ||
| Fuel metering pump, location/purpose | ||
| Heater circuit thermostat location/purpose |