GF83.70-P-4004A | Combustion air blower, location/task | 20.10.11 |
MODEL 168 with ENGINE 668.940
with heater booster
MODEL 202 with ENGINE 611.960
with heater booster
MODEL 210
with heater booster
MODEL 220 with ENGINE 613.960
with heater booster
MODEL 220 with ENGINE 628.960
with heater booster
MODEL 129 as of 1.6.97 with CODE (228) Stationary heater
MODEL 203 up to 23.4.04,
210, 215, 220, 230 with CODE (228) Stationary heater
MODEL 463 as of 1.6.94 up to 31.5.12 with CODE (H12) Auxiliary heater
Webasto Tele Thermo Top S
MODEL 209.3 up to 31.5.04 with CODE (228) Stationary heater
P83.70-0344-11
Models 129, 168, 202, 203, 209.3, 215, 220, 230
1 Combustion air housing
2 Fuel inlet
3 Burner housing
A6m2 Combustion air blower
Combustion air blower location | The combustion air blower (A6m2) is a constituent of the STH heater unit (models 129, 203, 209.3, 215, 230) or the STH or HB heater unit (models 168, 202, 220). Together with the combustion air housing (1), it forms an inseparable unit. | ||
Model 210 up to 31.08.96 with engine 602.982 with heater booster Model 210 with code (228) Stationary heater Model 463 as of 01.06.94 with code (H12) Webasto Tele Thermo Top S auxiliary heater | |||
Combustion air blower task | To provide a constant supply of combustion air for consistent fuel/air mixture formation during heater operation and rapid cooling of the STH heater unit or the STH or HB heater unit, and for combustion chamber purging during heater unit power-down. |
Henviste dokumenter
- gf8370p400401a Forbrændingsluftblæser placering