gf8330p2000a

Tempmatic air conditioning pushbutton control module position/function

Type gf · emne 83.30 · version 0103 · 2000-01-26

Gælder for: MODEL 210 with CODE (580) Air conditioning or Tempmatic for USA

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 83 Klimatisering › 83.30 Klimaanlæg — Serie 210

GF83.30-P-2000A

Tempmatic air conditioning pushbutton control module position/function

27.6.97

MODEL 210 with CODE (580) Air conditioning or Tempmatic for USA

Tempmatic air conditioning pushbutton control module position/function

P83.30-0851-11

1 Temperature selection wheels

2 Blower switch

3 Air distribution switch

4 Recirculated air pushbutton

5 EC pushbutton

Tempmatic air conditioning pushbutton control module position/function

P83.30-0874-01

Shown on residual engine heat recirculation (Codes 450, 670)

4 Rest pushbutton (is combined with the recirculated air pushbutton)

Function

The control and operating module (N19) automatic heater (HEAT) permits performance of adjustments required by the driver, such as:

Temperature by using the temperature selection wheels (1)

Air quantity by using the blower switch (2)

Air distribution by using the air distribution switch (3)

Recirculated air by pressing the recirculated air pushbutton (4)

Activation of the residual engine heat recirculation, with ignition turned off, by pressing the Rest button (4) with Codes 450, 670

Switching off the cooling by pressing the EC pushbutton (5)

Furthermore the control module integrated into the control and operating (N19) module takes over regulation and control of systems, such as:

comparison of the preselected / actual temperatures and adjustment of the air output temperature to the air outlets

automatic switching from fresh air to recirculated air

electrical actuation of the refrigerant compressor

actuation of the auxiliary ventilator

The control and operation module (N19) can be diagnosed so that faults arising are stored in a fault memory, which can be read out with the aid of the Hand-Held-Tester.

When changing the control and operating module (N19) a variant coding should be performed with the aid of the Hand-Held Tester.

Blower switch Location/task/function

GF83.25-P-2104A

Air distribution switch Location/task/function

GF83.25-P-2103A

Temperature selection wheel Location/task/function

GF83.25-P-2105A

Recirculated air pushbutton Location/task/function

GF83.40-P-2145A

EC pushbutton Location/task/function

GF83.40-P-2146A

Rest pushbutton Location/task/function

Special request

GF83.40-P-2148A

Henviste dokumenter