GF07.13-P-3011C | DFI AC compressor shutoff function | 27.6.95 |
ENGINE 602.982 in MODEL 210.017 /217 /617
P07.13-0395-76
Design
A1 Instrument cluster
A9k1 Electromagnetic clutch (A/C compressor)
CAN Controller Area Network (CAN data bus)
K40 Relay module (up to 02/97)
K40/4 Fuse and relay module (as of 03/97)
L5/6 Crankshaft position sensor
N3/8 DFI control module
N19 Tempmatic air conditioning pushbutton control module
N22 Automatic A/C push-button control module
R25/2 Accelerator pedal position sensor
Task
Switching off AC compressor in order to improve engine output when starting off.
Function
The Tempmatic air conditioning pushbutton control module (N19) or Automatic air conditioning pushbutton control module (N22) receives a signal from the instrument cluster (A1) which switches the AC compressor off or on depending on engine load and speed.
AC compressor cutoff is controlled by the DFI control module (N3/8) which communicates with the instrument cluster through the CAN data bus. The AC compressor is shut off with a time delay of up to 1 second.
The AC compressor is shut off if one of the following operating states exists:
Accelerator pedal depressed > 90 %
Engine speed < 1050 rpm
The AC compressor is switched on if one of the following operating states exists:
Accelerator pedal depressed < 90 %
Engine speed > 2500 rpm
| Relay module (K40) position/design/task/function | up to 02/97 | |
| Fuse and relay module (K40/4) position/task/function | as of 03/97 | |
| DFI control module (N3/8) input signals/output signals/ position/task/function | ||
| Crankshaft position sensor (L5/6) position/design/task/function | ||
| Accelerator pedal position sensor (R25/2) design/task/function | ||
| CAN data bus task/design/function | ||
| Tempmatic air conditioning pushbutton control module function | ||
| Automatic air conditioning pushbutton control module function | ||
Instrument cluster (A1): | |||
| K1 and K2 wire position/task |
Henviste dokumenter
- gf0704p4116h Positionsføler krumtapaksel placering/opgave/opbygning/funktion
- gf0704p5029h Føler for korrekt værdi placering/opgave/opbygning/funktion
- gf0713p3101h
- gf0713p3102c
- gf0713p3141h Sikrings- og relæmodul placering/opgave/funktion
- gf5400p0005c
- gf5430p2015a
- gf8330p2000a
- gf8340p2000a