ar8370w5975b

Remove/install temperature sensor

Type ar · emne 83.70 · version 0104 · 2004-09-30

Gælder for: MODEL 950, 952, 953, 954 with BODY 942.899 with CODE (H64) Eberspächer D9W hot water auxiliary heater'

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 83 Klimatisering › 83.70 Parkeringsvarmesystem, ekstra varmesystem, ekstra varmeapparat — Serie 942 (modeller 899) · Serie 950 · Serie 952 · Serie 953 · Serie 954

EinPAS 39 Varmesystem/ventilation/køling › 39.25 Parkeringsvarme/ekstra varmesystem › 39.25.12 Sensor/kontakt/ledningssæt — Serie 942 (modeller 899) · Serie 950 · Serie 952 · Serie 953 · Serie 954

AR83.70-W-5975B

Remove/install temperature sensor

6.6.96

MODEL 950, 952, 953, 954 with BODY 942.899 with CODE (H64) Eberspächer D9W hot water auxiliary heater

Remove/install temperature sensor

1 Tie strap

2 Tie strap

3 Cap

4 Cable retainer

5 Flat connector

6 Connector

7 Electrical line

8 Temperature sensor

9 Heat exchanger housing

10 Sealing ring

W83.70-0006-03

Remove/Install

1

Disconnect ground lead from battery

Do not interrupt main battery current in heater mode or in the run-on phase.

Danger!

Risk of injury caused by body parts being jammed and crushed when tilting cab

Ensure that no one is within the tilting range of the cab during tilting. Always tilt the cab all the way to the end position and secure with the safety strut.

AS60.80-Z-0001-01A

2

Tilt cab

3

Remove auxiliary heater control unit

AR83.70-W-5937A

4

Remove tie straps (1) and (2)

5

Detach cap (3) of cable retainer (4)

*BA83.70-N-1006-03A

6

Fold up cable retainer

7

Unclip flat plug (5) of chamber nos. 9 and 11 from connector housing (6)

*655589066300

8

Pull electrical line (7) through to temperature sensor (8)

9

Remove temperature sensor with sealing ring (10) from heat exchanger housing (9)

*BA83.70-N-1014-03A

10

Install in the reverse order

Danger!

Risk of explosion caused by fuel vapors igniting, risk of poisoning caused by inhaling combustible gases and risk of injury caused by burns during and after operation of heater unit

Do not operate stationary heater, auxiliary heater or engine with heater booster in closed areas or when refueling. Allow heater unit to cool down after operation and wear protective gloves.

AS83.70-Z-0002-01A

11

Check function of stationary heater

AR83.70-W-5302-02B

Stationary heater unit

Number

Designation

Models
950, 952, 953, 954
with body 942.899
with (CODE H64) "Eberspächer D9W" heater

BA83.70-N-1006-03A

Bolt, cap on burner housing

Nm

3.5

BA83.70-N-1014-03A

Temperature sensor to heat exchanger housing

Nm

3

Remove/install temperature sensor

655 589 06 63 00

Contact release