AR83.70-W-5807C | Remove, install combustion and heating air blower | 6.8.96 |
MODEL 375.4 with BODY 375.840 with CODE (H60) Warm air heater "Eberspächer D1 LP"
MODEL 944 with BODY 944.899 with CODE (H60) Warm air heater "Eberspächer D1 LP"
MODEL 950, 952, 953, 954 with BODY 942.899 with CODE (H60) Warm air heater "Eberspächer D1 LP"
MODEL 970, 972, 974, 975, 976 with BODY 972.899 with CODE (H60) Warm air auxiliary heater "Eberspächer" D1 LP
MODEL 950, 952, 953, 954 with BODY 940.899 with CODE (H60) Warm air heater "Eberspächer D1 LP"
W83.70-0083-06
1 Screw
2 Combustion and heating air blower
3 Gasket
4 Plug for flame sensor
5 Plug for overheating switch
6 Screw
7 Cover plate
8 Sealing ring
9 Sealing washer
10 Heat exchanger
| Removing, installing | ||
1 | Remove housing shells | ||
2 | Remove glow plug | ||
3 | Disconnect plug (4) for flame sensor and plug (5) for overheating switch | ||
4 | Detach heating air blower (2) | ||
5 | Remove cover plate (7), sealing washer (9) and gasket (3) | Installation: Replace sealing washer and self-adhesive gasket. | |
6 | Detach sealing ring (8) from heat exchanger | Installation: Replace seal. | |
7 | Install in the reverse order | ||
Danger! | Risk of explosion from fuel vapors, risk of poisoning from inhaling combustion gases and risk of injury from burns during and after operation of heater unit. | Do not operate stationary heater, auxiliary heater or engine with heater booster in closed areas or when refueling. Allow heater unit to cool down after operation and wear protective gloves. | |
8 | Check function of stationary heater |