ar8370w5807a

Remove and install combustion and heater air blower

Type ar · emne 83.70 · version 0112 · 2012-02-24

Gælder for: MODEL 375.4 with BODY 375.840 with CODE (H61) "Webasto" Air Top 2000 hot air auxiliary heater MODEL 944 with BODY 944.899 with CODE (H61) "Webasto" Air Top 2000 hot air auxiliary heater MODEL 950, 952, 953, 954 with BODY 942.899 with CODE (H61) "Webasto" Air Top 2000 hot air auxiliary heater MODEL 970, 972, 974, 975, 976 with BODY 972.899 with CODE (H61) Webasto Air Top 2000 hot air auxiliary heater MODEL 950, 952, 953, 954 with BODY 940.899 with CODE (H61) "Webasto" Air Top 2000 hot air auxiliary h

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 83 Klimatisering › 83.70 Parkeringsvarmesystem, ekstra varmesystem, ekstra varmeapparat — Serie 375 (modeller 4**, 840) · Serie 940 (modeller 899) · Serie 942 (modeller 899) · Serie 944 · Serie 950 · Serie 952 · Serie 953 · Serie 954 · Serie 970 · Serie 972 · Serie 974 · Serie 975 · Serie 976

EinPAS 39 Varmesystem/ventilation/køling › 39.25 Parkeringsvarme/ekstra varmesystem › 39.25.30 varmeapparat — Serie 375 (modeller 4**, 840) · Serie 940 (modeller 899) · Serie 942 (modeller 899) · Serie 944 · Serie 950 · Serie 952 · Serie 953 · Serie 954 · Serie 970 · Serie 972 · Serie 974 · Serie 975 · Serie 976

AR83.70-W-5807A

Remove and install combustion and heater air blower

16.2.12

MODEL 375.4 with BODY 375.840 with CODE (H61) "Webasto" Air Top 2000 hot air auxiliary heater

MODEL 944 with BODY 944.899 with CODE (H61) "Webasto" Air Top 2000 hot air auxiliary heater

MODEL 950, 952, 953, 954 with BODY 942.899 with CODE (H61) "Webasto" Air Top 2000 hot air auxiliary heater

MODEL 970, 972, 974, 975, 976 with BODY 972.899 with CODE (H61) Webasto Air Top 2000 hot air auxiliary heater

MODEL 950, 952, 953, 954 with BODY 940.899 with CODE (H61) "Webasto" Air Top 2000 hot air auxiliary heater

Remove and install combustion and heater air blower

W83.70-0647-06

1 Screw

2 Heating air inflow vents

3 Combustion and heater air blower

4 Gasket

5 Gasket

6 Insulation

7 Lower housing segment

Remove/Install

Danger!

Risk of explosion caused by fuel vapors igniting, risk of poisoning caused by inhaling combustible gases and risk of injury caused by burns during and after operation of heater unit

Do not operate stationary heater, auxiliary heater or engine with heater booster in closed areas or when refueling. Allow heater unit to cool down after operation and wear protective gloves.

AS83.70-Z-0002-01A

Danger!

Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices

No fire, sparks, open flames or smoking.

Wear acid-resistant gloves and clothing and safety glasses with side guards.

Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground.

Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

1

Disconnect ground lead from battery

Do not interrupt main battery current in heater mode or in the power-down phase.

2

Remove storage compartment

With body 942.899 only

AR88.60-W-3171A

3

Remove heater

Body 942.899

AR83.70-W-5302A

Bodies 940.899, 972.899

AR83.70-W-5302C

Bodies 375.840, 944.899

AR83.70-W-5302F

4

Remove upper housing segment and covers

AR83.70-W-5936-01A

5

Remove controller board

Do not touch controller board tracks.

AR83.70-W-5936A

6

Remove gasket (5)

Installation: Install new gasket

7

Remove heater from lower housing segment (7)

Installation: Insert heated-air inflow unit into the guide groove.

AR83.70-W-5807-01A

8

Remove heated air inflow (2) and insulation (6)

9

Remove combustion and heated air blower (3)

Installation: Install new gasket

Use Loctite to lock screws (1) in place.

*BR00.45-Z-1001-02A

10

Install in the reverse order

11

Check function of stationary heater

AR83.70-W-5302-02A

12

Measure emission level, adjust if necessary

AR83.70-W-1177A

Repair materials

Number

Designation

Order number

BR00.45-Z-1001-02A

Thread locking adhesive, Loctite 241

A 002 989 94 71

Henviste dokumenter