AR83.70-W-5757E | Remove/install glow pin | 6.3.07 |
MODEL 375.4 with BODY 375.860 with CODE (HH1) "Eberspächer D5W S" warm water auxiliary heater
MODEL 940, 942, 943, 944 with BODY 944.890 with CODE (HH1) "Eberspächer D5W S" warm water auxiliary heater
W83.70-1389-01
1 Auxiliary heating control unit
2 Combustion air blower panel
W83.70-1391-06
3 Plug housing
4 Electrical lines for glow pin
5 Glow pin
6 Fuel fitting
| Remove/install | ||
1 | Remove heater unit | ||
2 | Remove auxiliary heater control unit (1) | ||
3 | Remove panel for combustion air blower (2) | Installation: Do not damage the heat-protection mat. | |
4 | Detach electrical lines for glow pin (4) from contact cavities 9 and 12 of connector housing (3) | | |
| |||
5 | Unscrew glow pin (5) from fuel fitting (6) | Counterhold fuel fitting (6) at the hexagon. | |
| |||
6 | Install in the reverse order |
Auxiliary heater heating unit
Number | Designation | Model | Model | ||
BA83.70-N-1022-03A | Glow pin in fuel filler neck | Nm | 6 | 6 | |
000 589 13 99 30
MCP 2.8 / Fl blade. 2.8 / JPT / SPT
Blade holder with clamping pliers
220 589 01 99 50