AR83.70-W-5937E | Remove and install auxiliary heater electronic control unit | 6.3.07 |
MODEL 375.4 with BODY 375.860 with CODE (HH1) "Eberspächer D5W S" warm water auxiliary heater
MODEL 940, 942, 943, 944 with BODY 944.890 with CODE (HH1) "Eberspächer D5W S" warm water auxiliary heater
W83.70-1383-02
1 Bolts
2 Bolts
3 Auxiliary heating control unit
W83.70-1384-11
3 Auxiliary heating control unit
4 Plug connection
5 Grommet
| Remove/install | ||
1 | Remove heater unit | ||
2 | Undo bolts (1, 2) and remove auxiliary heater control unit (3) | Installation: Ensure that grommet (5) is correctly seated in the auxiliary heater control unit (3). | |
3 | Detach connector (4) from the auxiliary heater control unit (3) | Installation: Ensure that electrical lines are routed properly. | |
4 | Install in the reverse order |